20070212090500.pdfCity of Edmonds �PLAN REVIEW COMMENTS BUILDING DIVISION St. , s90 (425) 771-0220 DATE: February 12, 2007 TO: Allen Stroh h.stroh@ven'zon.net FROM: Jenny Readwin, Plans EY6 in RE: Plan Check # 2007-0075 Project: Stroh Addition Project Address: 24211 107' PL W During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) There is a copy of a 5' rear utility easement in this application. Please show easement on the site plan. 2) Specify cfm of all exhaust fans on the floor plans. Whole House fan is required to be 95-143 per the Energy Worksheet completed and the other bathroom is required to have a minimum 50 cfin fan. 3) Fireplace in the bedroom must be direct vent. Note on plans. 4) Show location of all smoke detectors throughout the existing residence. One is required in each sleeping room and in the hallway outside each separate sleeping area. 5) Provide crawlspace ventilation calculations and show size and location of crawlspace vents on foundation plan. 6) Show size and location of crawlspace access (required for both foundation areas). 7) Provide complete section view from the foundation through the roof. See attached sample plan for minimum requirements (foundation rebar, anchor bolts, wall stud size and spacing, roof framing members, etc.). 8) Wood floor joists in contact with concrete must be pressure treated. Note on plans. 9) Each truss is required to be anchored to bearing wall with approved framing clips. Note on plans. 10) Specify if foundation will be poured monolithically. If not then one #4 vertical rebar is required at no more than 4' on center. Specify on section detail. Also, R403.1.3 requires all vertical rebar to have a standard hook. Revise all foundation details to reflect. 11) Provide section detail through slab on grade foundation at the unheated storage area. 12) Provide clear foundation plan that shows which foundation detail applies where. Also bathroom addition is cut off the foundation plan. Please expand to clarify foundation to be added at this location. See enclosed sample foundation plan. 13) Specify footing size for porch post as well as post to footing and post to beam connectors. 14) Specify floor framing for the breezeway. 1 S} Specify roof framing for the bathroom addition. 16) Provide calculations for 4x10 headers including point loads from proposed ridge beams. 17) Add all Engineer's shear wall and holdown information to the plans including the schedule. Page 2 of 2 SAMPLE SECTION VIEW (FOR CONVENTIONAL LIGHT -FRAME WOOD CONSTRUCTION) Roofing material type and weather barrier Roof Slope (e.g. 3:12) Sheathing thickness, type, and nailing pattern (e.g. 112 CDX Plywood, 8dnails, 6" o.c. at edges and 12" o.c at field) ` Maintain 1" airspace with approved baffle Gutter connected to tighl!nod downspout Eave venting Three 2" holes per bay covered with 114" galvenized wire mesh Siding material type and weather barrier Sheathing thickness, type and nailing pattern (e.g. 112" CDX Plywood, Sd nails, 6" o.c. at edges and 12" o.c at field) 112" x 10" anchor bolt with nut and washer spaced at 6' o.c. maximum, with min. 7" embedment, 2 bolts per piece within 12" of each end. Plate washers are required for each bolt (2" x 2" x 3116" thick) 6" minimum wood - earth separation Grade shall slope away from foundation walls minimum 6 inches within the first 10 feet - Footing are drains require for all foundation walls tha l IIL enclose habitable or useable space below grade.: See footing drain detail for °T requirements, Attachment Ell C1. Footings must be placed on firm, bearing, undisturbed soil L:ktemp5building4handou6sfr%secticnC vsd updated 4106 Ceiling Insulation R -Value (e.g. R-30 batt) Ridge Board size Manufactured Truss/Rafter size, spacing and lumber specieslgrade (e.g. 2x8 HF#2 rafters at 24" on center) Ceiling JoistlCollar Tie size, spacing and species Rafters/Trusses must be anchored to bearing wall with approved framing clips (See Typical Construction Connectors) Double top plate Wall Insulation R -value (e.g. R-19 kraft paper batts face stapled) Sheetrock thickness (e.g. 112" sheetrock) Studs size, spacing and species (e.g. 2x6 HF#2 studs at 16" on center) DESIGN LOADS: Wind Speed: 80 mph Wind Exposure: B Seismic Zone: 3 Roof Snow Load: 25 psf Roof Dead Load: 15 psf Floor Live Load: 40 psf Floor Dead Load: 15 psf SCALE: 314"=1'-0" Subfloor thickness, type, and nailing pattern (e.g. 314" CDX Plywood, 8d nails, 6" o.c. at edges Floor Insulation R -value and 12" o.c at field) (e.g. R-19 batts) Floor Joist size and spacing (e.g. 2x10 HF#2 at 16" on center) Size of pressure treated sill plate (e.g. 2x6 pressure treated sill plate) #4 rebar continuous (typ) 6 mil vapor barrier throughout crawlspace See chart on page 4 for minimum foundation footing and wall sizes Concrete foundation N N Eo E o E o E o y $ ATTACHMENT C 12 L:ITEMMUILDINGIHANDOUT ICODES\Handouts WebpagelSFR B73.DOC Revised 5106 SAMPLE FOUNDATION PLAN INCLUDES 1ST FLOOR FRAMING SCALE 114" = 1'-0" 40'-0" 15'A" 10._g,. I1 1D,_g., I � g•_g,• �� g•.g,• I � i0'-6•' ^I ►I• ►ham 9'A", ►h / Proposed deck (see Deck Handout for information) Existing crawl spaceTHF911F, - Existing ---� access: 16" x 24'_�cPaha—Exisfin 2p) gI I IHoldown (e.g. E I I I HDSA, STHD14) m I I I I I I III 11 I 141 I Ill ' I I ' III I l l I 141 I III I I I I I I I III I I III I I A L-- P I.i I b!a ° I t Ills II" -'I1 I I N I III I j I la I I I E I I I-1 I crawl space I I I 4 c a I I I g l o f 1 1 I I Access: 16" x 24" I I I N ti l I ^a I I I E� I I I I 1 1 112x10 I I HF#2 16" I I tsxl o f I I I m I I 1 1 O.C. V l I d IIIA I I I III I E I. III I m! I f•I I I I I I I I I °' I m 1 -I I I Continuous) I I III I I I Fcundationl III i III (trP] I I I I I wT I I I I III I I� III I I I III I I I I I I I I I I I o c E I Existing 4 x 4 ! I Ipressure treated I I I ¢ I Crawlspace 1 I re u III post with post 1 1 1 I I I I 1 1 1 base (PBxx) and 1 14 I post cap (Pcxx) III 1 I I I I I I I 1 1 1 (typical all posts) I l I I III I I r I 9 al IL LI L I---jI1---f ABWP Existing Covered I l— 4 PorchIF I I I I I o= Existing foundation 1 4 Concrete Slab I ry m = Proposed foundation I I I I I ! 1 I Provide constfuction details and sections to I I I 1 clearly show code compliance I ! I I L-------� J I L-- ---- ABWP 101-6" 11 .. 25'A" ABW ` Holdown (e.g. I 50'x" HDSA, STHD14) —Provide 6 mil black polyethylene moisture barrier throughout craMspace, lap seams 6" and seal. —All wood in contact with concrete or exposed to weather must be pressure treated or naturally resistant to decay. "Footings to bear on 2000 psf. undisturbed soil. Specify Soil Type: i.e., Silty Gravel L'ltemplbuilding5handout5additionlfdnframe vsd -- 8)04 L:\TEMP\BU1LDINGq1AND0UT ICODE51Handouts Webpage\REMOADD B61 .DOC Revised 7/04 Detail Attachment F Holdown (e.g. HDSA, STHD14) Ledger size, lag bolti nail size and spacing with 0 Specified joist A hanger. Foundation Ventilation Calcs: 31 811 50=2.12 sf. Provlde six 12"x 6" vents covered with corrosion resistant screen. Note: vent net free area is 54 sq.in. taking into account 25% screened reduction. Crawlspace access In floor: 18"x24' min. . Holdown [e.g. HDSA,STHD14) ATTACHMENT B .11