Loading...
2007-0276 SFR(1).pdf City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Review Corrections Plan Check : Date: # 2007-0276 May 4, 2007 th Project Name/Address: Jakes Development/7511 176 ST SW th Contact Person/Address/Fax: Jakes Development/16430 6 Ave W Lynnwood, WA 98037/425-741- 7320/Fax: 425-741-7343/Cell: 206-387-6534/e-mail: jakesdevelopment@comcast.net Reviewer: Jaime HawkinsDivision:Engineering During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed: 1.Show the water meter at the property line. Please call out the type of material to be used for the water service line. If poly is used, add a not stating “12-gauge tracer wire required and grounded at both ends” 2.Extend the sewer main eastward up to the proposed sewer lateral. 3.Provide a six-inch sewer cleanout at the property line on the Right of Way side of the property line. 4.Show the edge of pavement. 5.Show the proposed curb/gutter and asphalt walkway along the entire frontage of the property. Curb/gutter, sidewalk, and driveway are to be installed per City of Edmonds standard details E2.8, and E2.12 Please add this comment to your site plan. 6.Show the minimum distance from the edge of pavement to the face of the curb. The minimum shall be 12-ft. 7.By installing the new curb/gutter 12-ft north from the edge of pavement the drainage ditch will have to be filled. A new storm line shall be installed at the new gutter line, which will require the installation of at least 2 new catch basins, one at east the other at the west, that shall be connected to the existing storm ditch by installing a 12-inch storm pipe armored with 2-4 inch quarry spalls. Please show the new catch basins, the 12-inch storm line connecting both catch basins, and the 12-inch storm line with quarry spalls. Please make sure to provide invert and rim elevations for all pipe and structure. 8.Relocate existing mailboxes. 9.The grading exceeds 500-cu-yds. Please contact the Planning Division for SEPA determination. DATE MAILED: 4/11/2007 PAGE __1__ OF _1__ Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator. Please contact me at 425-771-0220 if you have specific questions regarding these plan corrections. DATE MAILED: 4/11/2007 PAGE __1__ OF _1__