Loading...
20070301112921.pdfOV EDO City of Edmonds d PLAN REVIEW COMMENTS "' BUILDING DIVISION (425) 771-0220 DATE: March 1, 2007 TO: Dane and Marjorie Tomer D-MTOMER@peoplepc.com FROM: Jenny Readwin, Plans Exam ner RE: Plan Check # 2007-0226 Project: Tomer Carport Enclosure Project Address: 23723 77th Ave W. During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator on or before Friday Mauch. 30, 2007 or the file will be turned back over to code enforcement for further enforcement action. 1) Provide three copies of site plan scaled 1"=20' on 8 %" x 14" or smaller paper. See attached garage handout for minimum site plan requirements. 2) Note garage/dwelling separation on plans. Minimum %2" sheetrock required on garage side of wall and 5/8" type X on the ceiling when there is habitable space above and minimum 20 minute rated or 13/8" solid core door. 3) Expand floor plan to show all doors and room uses in the existing residence ( i.e. kitchen, bedroom, living room, etc.) around this carport that is being converted to a garage. Clarify if water heater storage area is existing or proposed. 4) Provide a section detail from the foundation through the roof showing, footing/foundation dimensions, rebar, stud size and spacing, top plate, roof construction, etc. See attached garage handout for sample section detail. Specify on detail what is existing and what is proposed. 5) Provide roof framing plan and specify what is existing and what is proposed. See attached handout for sample roof framing plan. 6) Per R403.1 a continuous foundation is required to support all exterior walls. Provide a foundation plan showing proposed and existing foundation. If a continuous foundation is not provided then structural calculations stamped and signed by a Washington State Licensed Professional Engineer will be required. 7) Exterior walls do not meet minimum wall bracing required by IRC 602.10. Provide lateral calculations stamped and signed by a Washington State Licensed Engineer or alter plans to meet minimum wall bracing requirements. #B36 city of edmonds development information Garage Permit Submittal Requirements PERMIT REQUIRED: A permit is required for the repair, alteration or construction of a garage. CODES: International Building (IBC) and Residential Code (IRC) (2003 Edition) Edmonds Community Development Code (ECDC) FEE: Based on square footage SUBMITTAL REQUIREMENTS: 1. ❑ A Critical Areas Determination, issued by the Planning Division (See Handout #P20) 2. ❑ Drainage Pian - Three (3) copies with worksheet or required calculations (See Handout #E72) 3. ❑ Grading Plan --- When grading exceeds 50 cubic yards (See Handout #B37) 4. ❑ Plot Man - Three (3) copies, scaled 1"-20' (one (1) of the three plot plans must be no lamer than 8 %z" x 14") (See Attachment A) 5. ❑ Working Drawings - Two (2) complete sets with the following: a) General Notes b) Foundation Plan and Details c) Construction and Section Details d) Elevation Views e) Height Calculations (See Handout #B41) i.:1TEMKBU1LDINGIHANDOUT ICODESIGARAGE B36_DOC Revised 7104 1. CRITICAL AREAS CHECKLIST (See Handout #P20) A Critical Areas Determination, issued by the Planning Division, must be completed and on file with the City. Provide applicable information as indicated by the decision. 2. DRAINAGE PLAN (See Handout #E72) Sites that currently do not have an on-site drainage system may be required to install such a system depending upon site location and the scope of the proposed work. Site with existing drainage systems may need to be upgraded to accommodate new proposed impervious area. Impervious area includes; the building pad with eave overhangs, paved or graveled areas, solid surface decks, patios, walkways, breezeways, awnings, accessory structures, sidewalks and driveways. On the plot plan, indicate the square footage of impervious area existing on the site prior to July 1977, impervious area added to the site since July .1977, and the amount of impervious area proposed under the current project. 3. GRADING PLAN (See Handout #B37) When grading on site exceeds 50 cubic yards, submit three (3) copies of a grading plan, scaled 1 "-20', with yardage calculations specifying the number of cubic yards to be removed, filled or graded. Show existing grade contours and proposed finished grades at five (5) foot intervals. Refer to City Grading handout for more specific information and submittal requirements. NOTE: When grading exceeds 499 cubic yards of f ll, excavation or cut, a SEPA Environmental Checklist (See Handout #P71) and Adjacent Property Owners list (See Handout #P2) must be submitted. Contact the Planning Division for fees and processing information_ 4. PLOT PLAN (See Attachment A) -Three (3) copies, scaled 1"-20', one (1) of the three plot plans must be no larger than 8'/2" x 14" with the following: 1) Property owner's name, tax account parcel number and street address. 2) North arrow designation, Scale 1'- 20' and property line dimensions_ 3) Streets, approaches, driveways, sidewalks, alleys, easements (public and private), paved areas, street dedications and adjacent City right-of-way (developed or undeveloped), show all dimensions. 4) Existing water courses of any size, i.e., streams, creeks, ponds, ditches, etc. 5) -Dimension all buildings and structures (label them existing or proposed), indicate setback distances, lot area and lot coverage. .b) Building height calculations. (See Handout #B41 and page 3 'of this handout) 7) Surface elevations at each corner of the lot. Topographic lines at five (5) foot intervals for slopes 15% or less and at two (2) feet intervals for slopes greater than 15%. Indicate driveway slope. 8) Impervious area calculations. I.: ITEMMUILDINGUL4.NDOUT ICODESIGA.R.AGE B36.DOC Revised 7/04 5. WORKING DRAWINGS Two (2) complete sets with the following: A. GENERAL NOTES: General notes shall include the following: 1) Name and address of property owner and project contact person. 2) Legal description, tax account parcel number, copies of recorded access or utility easements. 3) Zoning, lot square footage, building pad area, lot coverage and percentage of coverage. 4) Design loads: dead, live, wind (wind speed 85 mph with 3 second gust, exposure B or C, See R301.2.1.4), snow load 25 psf, Seismic Design Category D2. 5) Soil classification (i.e., soil bearing 2,000psf), concrete strength, reinforcement steel grades. 6) Timber species and lumber grades, plywood span indexes for roof, wall, floor sheathing. 7) Nailing schedules for floor, wall, roof sheathing per IBC Table 2304.9.1 and IRC 'Table R602.3(1). B. FOUNDATION PLAN DETAILS: (See Attachment I3, C & D) A site specific foundation plan is required and shall be designed based on the soil classification determined on site. Show the following: 1) Slab, footing and wall dimensions (thickness and height), grade and size of reinforcing steel, spacing and size of vertical and horizontal rebar and anchor bolts, location of proposed holdowns or other seismic connectors. 2) Use the foundation plan also as a floor plan showing the use of all space(s). Indicate plumbing and mechanical fixtures and floor material. For attached structures show openings (door and windows) in common walls and use of rooms adjacent to the structure. C. CONSTRUCTION AND SECTION DETAILS: (See Attachment C) 1) Framing cross section from foundation to roof including; stud, post, joist, rafter, truss size and spacing, show direction, support, connections, blocking, headroom, finish materials, siding, roof pitch, and ventilation. 2) Exterior wall bracing is required at each building comer. Typically, bracing is satisfied by installing solid 4 foot sheathed panels at each building corner. A code exception (IRC R602.10.6) allows an alternate braced panel for one-story designs provided that panels are a minimum of 2'8" wide with two (2) holdowns (min. uplift 18001bs) with two anchor bolts. (See Attachment E) 3) Show post and beam connection details (positive connection is required at all posts and beams). (See Attachment D) Provide beam calculations for all beams. 4) Provide a roof -framing plan. (See Attachment F) All rafters/trusses shall be anchored to bearing walls with approved framing anchors: Provide truss drawings to building inspector at the training inspection. 5) If the garage is attached to existing structure, provide detail showing how existing construction will be tied into new construction. NOTE: Plans which do not meet conventional construction as detailed in the International Residential Code, must be designed in accordance with the structural provisions of the International Building Code by a Washington State licensed Engineer with supporting calculations included in the submittal. D. ELEVATION VIEWS: (See Attachment G) 1) Front, rear, sides, finished slopes, average grade, finished floor elevations. 2) Show location and size of windows, doors, sliders, skylights, etc. 3) Show actual and maximum height of the residence taken from the average grade as determined by the height calculations. L UEMMBUILDINGMANDOUT ICODESIGARAGE B36.DOC Revised 7104 E. HEIGHT CALCULATIONS: (See Attachments A & G and Handout #B41) NOTE: Detached structures in residential zones are limited to 15 feet in height. 1) Stake out the smallest rectangle that encompasses all four corners of the building at original, undisturbed soil. Do not include eaves if they project no more than 30 inches. 2) Select a datum point to establish a starting mark to compute height calculations. The datum point must be a permanent point of reference and be located off site (i.e. top of a manhole cover, fire hydrant, or street monument). Reference the datum point at elevation +100- 3) Calculate the difference in elevation at each building corner of the rectangle, above or below, the dation point mark of +100. 4) Add the four corner elevations and average --this figure is the average grade. 5) Add 15 feet to the average grade, this is the maximum height allowed. 6) On the plot plan show the grade elevations at each building comer, the datum point, the original grade, the average grade and the actual height. 7) if the structure is attached you must include the existing and proposed structures within the smallest rectangle that encompasses all four corners of both buildings in order to determine the average grade. From the average grade the maximum height would be 25 feet for attached structures_ NOTE- THE PURPOSE OF THIS HANDOUT IS TO ASSIST THE PUBLIC IN COMPLYING WITH DETAILED PERMIT SUBMITTAL REQUIREMENTS. IT IS NOT A COMPLETE LIST OF PERMIT OR CODE REQUIREMENTS AND SHOULD NOT BE USED AS A SUBSTITUTE FOR APPLICABLE LAWS AND REGULATIONS. IT IS THE RESPONSIBILITY OF THE OWNER/DESIGN PROFESSIONAL TO REVIEW THE SUBMITTAL FOR COMPLETENESS. ONLY COMPLETE APPLICATIONS WILL BE ACCEPTED BY THE MY FOR REVIEW_ L:ATEMPIBUILDINGIHANDOUT ICODESIGARAGE B36.DOC Revised 7104 SAMPLE PLOT PLAN Scale: V=20' IMPERVIOUS Si RFA_CE CALCS +105 Exist_ Building Roof Outline: 2500 sf. (constr. prior to 197'1) I Existing Patio: 200 sf- (constructed in 1987) _ Proposed Garage: 500sf. +100 J Proposed Drivetivay: 610 sf. Drive,vay to be Removed: 457 st HEIGHT CALCS / / A. = +99' B=+107' / -{ C = +100' D=+104' f O AVE GitADE = 102.5' I � en ACTUAL =125' , % 1 ave overhang AIA7tINTUM =127.5' A / - g ! 1 •� +99•i i_ .. +Iut LOT COV ERA GE: Patla.l' Existing; i • tD 2875 SQ.FT- (21%) " zoo,'A. ] r a.: Residence ]: 2300 sq.ft ] LOT AREA: 13,527 SQ.M N l i i l i E E i ] w _ _ I Proposed Existing r Garage i Covered Parch j 500 sq.ft. t 75 sq.ft. C .............. L_ ,'� '- +104 +100 Removeu;��'r5.1.tiz Property Line Exisfng EiaY `� '�'as�,�""•"..t°-'5 � `"'`' Q, driveway auf:l} 1457 sq.fL)�{Fr+i"�s , _fir `•' 100, Driveway Slope: 6% MAIN STREET DATUM PT- +140' ..� Center of Right -of -Way ' ss Tap of S5 i4laiibolc Cover L:lkemplbuddinglhandautkgaraoa4oloLvsaB011 ATTACHMENT !S PLOUSITE PLAN CHECKLIST ❑ Property owner's name, street address and Snohomish County Tax Parcel Number. ❑ North arrow designation and all Plot/Site Plans scaled at 1 "=20'. Q Streets, approaches, driveways, sidewalks, alleys, easements (public and private), paved or graveled areas, street dedications and adjacent City right-of-way (developed or undeveloped). Show dimensions (width and length) of each feature. ❑ Side sewer stub out at property line, existing or proposed sewer line, existing or proposed water meter location and water service line; all other site utilities (existing or proposed), i.e_, gas, cable, power, phone, fire hydrant, telephone pole, utility transformers, etc. ❑ Existing physical features and water courses of any size (i.e., streams creeks, ponds, culverts, ditches, drainage courses, etc.). ❑ Grade elevations at the four corners of the property. Topographic grade changes at every two foot interval_ Calculate lot slope and maximum driveway slope. ❑ Impervious surface calculations. (Refer to separate Storm Drainage Handout E72). ❑ Dimension all existing and proposed buildings and structures; show setback distances to property lines; include accessory structures and projections/cantilevered structures, bay windows; decks, porches, hot tubs, pools, chinmeys, roof overhangs, cave lines, breezeways, patios, sheds, pool mechanical rooms, walkways, driveways, fences, etc. ❑ Lot area and lot coverage calculations. ❑ Retaining wall or rockery location(s) with typical section detail. (Refer to separate Rockery and Retaining Tull Handouts #B62 & #B63), include top and bottom elevation every 5 feet. .❑ Building height calculations. Show smallest box/rectangle encompassing all four corners of the building, average grade, actual height, lowest footing elevation, and maximum allowed height (See Handout ##B41). Datum point must be located off-site (i.e., top of sewer manhole lid, top of fire hydrant, etc.) and must be a fixed point of reference that will not change during the construction project. It is the owner/applicant's responsibility to submit a true and accurate plot/site pian to the City for review. LATEMKBU1LDiNMANDOUT iCODESTLOTPLANCKLST B57 -doe Revised 10/05 20' 0" rt C M p fp =1 n O =r •O f� C7 � "' � .�+ Q' CD Ej- (D At SEr m Q 4 - (D at m S SD T. S z ABWP .� d -W' g------------------------------- _ ■ D 03 n 03 .-..._sem= _ �...��-:F'.f-a._.... `elr. .-. :ri�♦ ° ti �' ' t ♦t't♦w ♦ \•; ♦\\'i!♦ a -3 a'-� o o a n OJi_.y--------------_------------- x (Dol n a o 0 9z _ _-__ aw 0 3:n RL a a i a g Z� ,�. X 507 to Dai M 3 e i W Amo Xmm • � E I 4 -0 W y �a vt m cn - i I S7."�i. m y. C] \ tp to E w0 0 4) O s0) v co I ` ao n > o° S y 7C 0 O <D 0 � j• as � s Ic { A C C,a D� i CD 0 a iNI I <0 C° Q Q cG O S i I m N p N ! I I 0 O z c f m r fop � n �"3 a j IDD CAC� m �� w N E I W 3 i j c C 0 CD Q i - I a' w (J) .fp G �3t CDCD a.�+ Co y 3 ix E 3 Q- a ro w 3 0m CLI m in t Ilk I o = oro o m o, i I D co CD I N � I Q I i � I i I 4'- 0. CE "- 1 _— o ———— — -"----- ————— ———— — — — — -- -- -- - - - - - — _ - ' E --------Bwp--- cn w 3 00 M 0 r4l I R 0 ■ a 0 MM% Mu ABWP .� n _ ■ D 03 3' 0" n 03 n C') 0 a -3 a'-� o o a n � x (Dol n a o 0 9z aw 0 3:n RL a a i a g Z� ,�. X 507 to Dai M 3 'U W R M CD �*CD � �a vt m - v tp m cn w 3 00 M 0 r4l I R 0 ■ a 0 MM% Mu SAMPLE SECTION VIEW SCALE: 314"=V-0" Roofing material type and vapor barrier (e.g. asphalt shingles des w130# felt) ST, d'VP c Sheathing thickness and type acing (e -g- %" CDX plywood, 8d nails, �ye.yp oL� 6" a.c. at edges and 12" in field) _� d Cus aRVNFRidge Board size '�{acOle e . 0- 261DM Ceiling Joist/Collar Tie size, spacing and species DESIGN LOADS: Roof: 25 psf snow load Wind Speed: 85 mph Wind Exposure: B Seismic Zoite: Q2 6" minimum wood earth separation 4" perforated drain pipe in washed gravel -- IIII�I ltemplbuildinglhandoutlgaragelgarsectl.vsd 8104 Raftersfrrusses must be anchored to bearing wall with approved framing clips (See Typical Construction Connectors) Double top plate Siding material type and weather barrier Sheathing thickness and type and nailing pattern (e.g. %" plywood, OSB, 8d common nails, 6" o.c_ at edges and t2" o -c- field) Studs size, spacing and species (e.g. 2x4 HF#2 @ 46" o.c-) 112" x 10" anchor bolt with nut and washer spaced at 6' o.c. max., with min. 7" embedment, 2 bolts per piece within 12" of each end_ Plate washers are required for each bolt (3" x 3" x 714" thick) Size of pressure treated sill plate III- Ilill #4 horizontal rebar continuous (typ) #4 vertical rebar at 48" o.c_ ]z Footings most be placed on firm CO bearing undisturbed soil Concrete foundation ATTACHMENT C z a EL 0 ra •'� Qoao r r - - • �rr�rJ wrr 0 0 MI. C). ct 0 0 0 0 0 0 Alternate Braced Wart Panel for a. 1 -story Structure (IRC R602.1.6) NOTE: This panel may be used in place of any braced wall parcel required by IRC R602.10.4. For all other wall bracing that does not meet R602.10, lateral calculations stamped and signed by a Washington State Licensed Professional Engineer must be provided. 1t4 rebar con top and bi Minimum 318" thick sheathing nailed with 8d nails at 6" o.c. at edges and 12"o.c. in the field. is Holdown with minimum 1800 lb. apacity_ Note specific holdowns or options on the plans for the 'actor that meet the 18001t ;ment. Caution on minimum edge ce'required foundation wall width, in embedment requirement, etc.. ichor baits embedded a im of 7", spaced at panel points Continuous Foundation LUempt . usicrn9u,ana«utazagelcaf—auvw.vsc-PO4 ATTACHMENT E Truss Example: Manufactured trusses at 24" o.c. Truss drawings must be stamped and signed by State licensed Professional Engineer and provided to the Building Inspector at framing inspection. All trusses shall be anchored to the bearing walls with approved framing.clips. Rafter Example: 2x8 HF#2 at 24" o.c. All rafters shall be anchored to the bearing walls with approved framing clips. Sample Roof Plan Tri sp ATTACHMENT F LatemplbuildinglhandoutlgarageVooipin_vsd — 8/04 A co O C m r - m C D 0 z z m D Q a rt 0