Loading...
20070306154233.pdfCity of Edmonds O ti � ,moo PLAN REVIEW COMMENTS r. € BUILDING DIVISION est' PAP (425) 771-0220 DATE: March 6, 2007 TO: Larry Deisher 1pnw@verizon.net FROM: Jenny Readwin, Plans Exam' e RE: Permit # 2006-0953 Project: Detached Garage Revision Project Address: 7025 174th St SW During re -review of the above noted revision, it was found that the following information, corrections, or clarifications are needed. 1) Revise site plan to show new smaller detached garage (22'x22'). Also provide revised height calculations for new 9' wall and 5:12 pitch roof. Show average, maximum and actual heights on the elevation views. Please provide 3 new site plans scaled 1"=20' and one on 8 %2" x 14" or smaller paper. 2) Also on the site plan re -label proposed structure (i.e. unheated shop). Without garage doors this is no longer a garage. 3) Specify on the plans if the show will be heated or unheated. If heated, specify how it will be heated (furnace, wall heaters, etc.) and how it complies with the 2004 energy code (R38 ceiling, R21 wall and R-10 slab insulation. 4) Note on plan says add 4' high retaining wall engineering by others. Please submit details and engineering for proposed 4' retaining wall.