20070410164310.pdfOV t D City of Edmonds 0 PLAN REVIEW COMMENTS - BUILDING DIVISION �St. t s90 (425) 771-0220 DATE: April 10, 2007 TO: Ray Webber 24323 Cedar Way Mountlake Terrace, WA 98043 FROM: Jenny Readwin, Plans Ex finer RE: Plan Check # 2007-0290 Project: Garage Remodel/Grading Project Address: 23327 92nd Ave W. During re -review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) 4/10/07 Grading plan submitted shows 0-9. S' rockery proposed along the South property line. See attached Rockery handout. Provide top and bottom wall elevations at 5' intervals as well as details and calculations stamped and signed by a Washington State Licensed Professional Engineer. Peer review will be required at owners expense. Provide site plan scaled no smaller than 1 "=20' showing garage, driveway and all existing and proposed grades including grading calculations for proposed grading. Note: grading must be done at the same time as the garage floor to avoid placing a surcharge on the foundation wall because of unequal backfill. 2) ok 3) 4/10/07 for existing furnace and water heater please specify if these are gas appliances and if so how they will be elevated minimum 18" above new garage floor. Application form specified washer hookups in the garage. Please show location of washer and dryer and specify if the dryer will be gas. 4) ok 5) ok b) 4110/07 Because the wall is existing a Washington State Licensed Professional Engineer must provide calculations to justify that the existing foundation is capable of supporting surcharge. We can not assume that the car will stay within line shown on details provided. Provide section detail for the foundation between the existing residence and the garage to show that a surcharge will not be placed on the existing foundation wall (i.e. is there crawlspace under the existing house? Unequal backfill?).