20070420080258.pdfo� EI) City of Edmonds Q6PLAN REVIEW COMMENTS BUILDING DIVISION Fst. 1 g90 (425) 771-0220 DATE: Apri120, 2007 TO: Randal J Munson randy.munson@comcast.net FROM: Jenny Readwin, Plans Exa ne RE: Plan Check # 2007-0164 Project: Classico Homes SFR Project Address: 945 Glen St. During re -review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) ok 2) ok 3) ok 4) ok 5) ok 6) ok 7) ok 8) ok 9) 4/20/07See attached additional comments. See attached structural comments from city consultant. Respond to each item in writing. Eagle Eye Consulting Engineers, P.S. PO Box 523 Olalla, WA 98359 hoytjeter@centurytel.net 360 874 0562 Fax 360 874 0591 To: Theresa Umbaugh 121 5th Avenue N Edmonds, WA 98020 Re: Classico Homes 945 Glen Street Edmonds, WA 98020 Plan Review # 2007-0164 Second Letter Date: Tuesday, April 17, 2007 EECE # EDM 07-07 (2) Structure Stated Area S.F. First floor 2085 Second floor 1894 Total 3979 Garage 785 Total 4764 Porch 60 Covered Porch 88 gpper Floor Deck 12 Grand total 4924 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The fallowing comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the Structural requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Page 2 of 3 EECE#: EDM 07-07 (second letter) Classico Homes STRUCTURAL COMMENTS General 1. 3. The drawings should clearly specify the requirement for the soil at the site. Nothing is specified at this time. How were the foundations system determined for this site with out this information provided? Please add this to the drawings. R401.2 The response state to see sheet A-1.There is not any sheet Al in the set. Please submit this on response. Sheet A-6 FOUNDATION PLAN: 2. 4. EOR, please provide analysis for the foundations below the columns shown. None was submitted in the analysis to justify the size sizes specified. Only one footing was submitted on the response. There are other footings that required analysis to be submitted not only the one location. For example the 27'X24" footing. 3. AOR there appears to be no footing specified under the garage RWS wall. Please add the required information at this location. Sheet A-7 UPPER FLOOR/LOWER ROOF FRAMING PLAN: 4. 7. When different width beam frame into a wood column a detail is required to show how the forces will be transferred. For example beam mark 7 and beam mark 8 have a width 5-114 and 7" respectively. Please add detail at this location to show how the required forces will be transferred. More information is required then just stating 6x6 wood columns. The revision to change the width is fine but still the drawings do not specified the required connections of the wood post to the beams. This information should be clearly added to the drawings for all post to beam connections. S. 16. EOR, there appears to not be a complete load path to the SW 2. Shearwall number 1, as shown on sheet A8 at bedroom number 4, has no method to transfer to the exterior shear wall (SW2) at the exterior wall located at the study. Submit analysis and details to transfer this lateral force. The response states see response from Reed and associates. There was not any response in the submitted packages. Please submit this on response. Sheet A-8 UPPER ROOF FRAMING PLAN: 6. 18. EOR, please sped the required collector element to transfer the shear force to the interior wall at bedroom number 2. There is not method specified to transfer this force at this location. The drawings still do not show in collector elements for the interior shear walls. The response states see response from Reed and associates. Page 3 of 3 EECE#: EDM 07-07 (second letter) Classico Homes There was not any response in the submitted packages. Please submit this on response. Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (360) 874-0562 between 8:00 a.m. and 5:00 p.m. By: Hoyt Jeter, P.E. President