20070502142813.pdfof EDS City of Edmonds O PLAN REVIEW COMMENTS BUILDING DIVISION Fs r. X90 (425) 771-0220 DATE: May 2, 2007 TO: Michael Kerr mkerr@chateaued.com FROM: Jenny Readwin, Plans Exa ine RE: Permit 4 2006-0942 Project: Rockery Revision Project Address: 8202 190t' Street SW During re -review of the above noted revision, it was found that the following information, corrections, or clarifications are needed. 1) Please clarify distance between tiered rockeries. Per City of Edmonds rockery handout the upper rockery tier shall be setback from the lower rockery tier a distance equal to or greater than the height of the lower rockery tier. If this is not the case then the lower tier shall be considered to support a surcharge from the upper tier which is not permitted. See attached handout.