Loading...
20070508094053.pdf1-1) c 1891) CITY OF EDMONDS 121 5TH AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 • FAX (425) 771-0221 Website: www.d.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering May 8, 2007 Falcon Ridge Homes, LLC Fax (866) 312-8468 Re: Height Survey for Permit BLD2006-0924 at 8012 24011, Street SW GARY HAAKENSON MAYOR The City received a height survey stamped by David G. West Jr., Surveyor and upon review it appears his survey is based on finished grades. Height calculations are required to be calculate based on original grades as shown on the approved site plan (ECDC 21.40.030). Based on the height calculations shown on the approved site plan the maximum allowable height is 151.75. Note the survey is showing actual height at 152.68 which is presumably still over the maximum allowable height since the surveyor used the same datum point from which the approved height calculations were based. In order to resolve this issue instruct your surveyor to re -shoot height based on city approved height calculations or acknowledge that the building is 11.6" over height and provide revised plans to show how the roof framing will be altered to met the maximum allowed height. Contact Gina Coccia in Planning if you have questions regarding the city's height codes and/or variance criteria. yl JE Ay Readwin P ans Examiner • Incorporated August 11, 1890 • Sister City - Hekinan, Japan Height Calculation/Grading Verification Worksheet Z Address: o Z. "'/ 'S'Lk Permit #: -.c—(,G Date: 7 A. Datum Point: B. Daturas Point Elevation: C. Average Grade: 7 g V9 3. MaximumElevation Allowed:/2z:--=(average grade) + 25' = 4. Reference Point Elevation Shot to House: 64 0/ 2 (datum elevation) +Z 3.-`— (grade to transit level line shot to house) 6. Measurements from line shot onto house to roof ridge: Total Vjj Zf 2Sf n � 7. Actual Elev^ati (reference point elevation) +Z3-n(measurements from IV ED Conclusion: , (actual) is greater / i than (allowed); therefore the house is/ is not over the height requirem nt per ECDC 16.20.30 requirements EWILDING DEPT. L_1TEMPIBUILDINGIMISC1Height CalcuWionGrading Verification Worksheet.doc 5 4 ; V9 3. MaximumElevation Allowed:/2z:--=(average grade) + 25' = 4. Reference Point Elevation Shot to House: 64 0/ 2 (datum elevation) +Z 3.-`— (grade to transit level line shot to house) 6. Measurements from line shot onto house to roof ridge: Total Vjj Zf 2Sf n � 7. Actual Elev^ati (reference point elevation) +Z3-n(measurements from IV ED Conclusion: , (actual) is greater / i than (allowed); therefore the house is/ is not over the height requirem nt per ECDC 16.20.30 requirements EWILDING DEPT. L_1TEMPIBUILDINGIMISC1Height CalcuWionGrading Verification Worksheet.doc 8012 240TH ST S.W. 136 - - r 10, N ; N I ^ OF 1 z 24dth W' 1 1 ! 171.62' N88'0 x'21 "E 1 40.01' �� 1 , HEREBY WEDICATEkl THE �� OF EDMONDS 10.01' 171.62' N8S' 1 54.81 — `. � PT A \ ,tB7.4 131.6 �, ti 04 n [0.3 S-: � �, � N PT D_ �129:8 �r � NW06'21 E N88. D6'2tfc" C / / 96.8 Delta=90' x — Uettc�r. � r R=20.D0 i �✓ i� ��JrI r'� R 31, Vt 3.143 S.F. L=31.42 �f it PROAD `Q' =} — t i o NST 15'14"E ui 60.00' 30.00' i I i 1 i HEIGHT CALCULATION PT. A = 131.6 PT. 8 = 127.4 PT_ C 121.3 NP y 5°p :' PT. D = 123.8 � MAY -- 510.7 / 4 = 127.68 + 25' — 152.68 . —