PLAN REVIEW COMMENTS
BUILDING DIVISION
(425) 771-0220
TO: Rob Jordan
Pryde Development Group
E-mail: rjordan.prydegroup@gmail.com
FROM: Ann Bullis, Assistant Building Official
RE: Plan Check #2007-0230
Project: Summit Remodel
Project Address: 8503 Bowdoin Way
During re -review of the plans for the above noted project, it was found that the following information,
clarifications or changes are needed. Provide written responses to each comment and where changes can be
found on. the plans. Please submit revised plans/documents to Marie Harrison, Permit Coordinator.
1. The architectural plans (stamped by James Thomas, Architect), only appear to apply to one dwelling
unit. It is not clear on the plans provided what work is proposed at what locations and for what units.
Provide complete floor plans of the building showing the proposed location for:
a. Each ventless washer/dryer unit
b. Laundry room exhaust fans with vent path to the outside, maintaining 3 feet from building
openings
c. Cross-reference where each submitted plumbing schematic applies
d. Cross-reference where the lined joist bay detail will be used to run the exhaust fan ducts to
the exterior of the building.
e. Where lined joist bays will not be used to run the exhaust fan ducts to the exterior of the
building, show how the I -hour floor -ceiling and wall assemblies will be maintained, such as
with soffits not penetrating the 1 -hour assemblies, etc.