Loading...
20070518092852.pdfDATE: May 18, 2007 City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 TO: Rob Jordan Pryde Development Group E-mail: rjordan.prydegroup@gmail.com FROM: Ann Bullis, Assistant Building Official RE: Plan Check #2007-0230 Project: Summit Remodel Project Address: 8503 Bowdoin Way During re -review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Provide written responses to each comment and where changes can be found on. the plans. Please submit revised plans/documents to Marie Harrison, Permit Coordinator. 1. The architectural plans (stamped by James Thomas, Architect), only appear to apply to one dwelling unit. It is not clear on the plans provided what work is proposed at what locations and for what units. Provide complete floor plans of the building showing the proposed location for: a. Each ventless washer/dryer unit b. Laundry room exhaust fans with vent path to the outside, maintaining 3 feet from building openings c. Cross-reference where each submitted plumbing schematic applies d. Cross-reference where the lined joist bay detail will be used to run the exhaust fan ducts to the exterior of the building. e. Where lined joist bays will not be used to run the exhaust fan ducts to the exterior of the building, show how the I -hour floor -ceiling and wall assemblies will be maintained, such as with soffits not penetrating the 1 -hour assemblies, etc.