20070521131558.pdfa� ono City of Edmonds M PLAN REVIEW COMMENTS BUILDING DIVISION Fsr 1 �q� (425) 771-0220. DATE: May 21, 2007 TO: Mitch Kent Mahlum Architects FAX: 206-441-0478 FROM: Ann Bullis, Assistant Building Official. RE: Plan Check 42007-0366 & 2007-0365 Project: Remodel Buildings F & H Project Address: 23200 100`x' Ave W During re -review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Provide written responses to each comment and where changes can be found on the plans. Please submit revised plans/documents to Theresa Umbaugh, Permit Coordinator. 3. .. 4. Previous items 2b & 3: The Building Official did not approve the Alternate Design request for the reduced occupant load in the Staff Lounge, therefore 2 exits are required. Revise plans to show second exit, and also revise Sheet G-002 to show the correct use, occupant load and exits. Previous item 5: The egress gate detail has still not been provided. We only received the manufacturer's information sheet for the Detex EA -500 Exit Alarm. Sheet A-113 at the egress gates refers to detail 02/A402, which refers to 04/A-403 which does not show the egress gate detail (it shows an elevation of H31 which appears to also be an incorrect room number — please coordinate). Previous item 6 and Architect letter dated 5118/07: Update plans with code information provided in 5/18/07 letter. Also, update wall assemblies to be 1 -hour fire rated, and provide listed and tested assembly reference (i.e. from Gypsum Fire Resistance Design Manual, UL Directory, IBC Chapter 7 tables, etc.). Note the complete construction requirements of assemblies on the plans so they are constructed and inspected properly in the field. Provide listed and tested 1 -hour fire stopping assembly details and reference number (such as from. UL Directory), or list as deferred submittal on the coversheet of the plans. C. 180) May 21, 2007 CITY OF EDMONDS 121 5TH AVENUF NORTH • EDMONDS, WA 98020 • (425) 771-0220 • FAX (425) 771-0221 Website: www.dedmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Mr. Gerald Reifert, AIA Mahlum Architects 71 Columbia, Suite 400 Seattle, Washington 98104 RE: Scriber Lake High School Remodel Establishing Maximum Occupant Loads Dear Mr. Reifert, GARY HAAKENSON MAYOR In response to your request for alternate design to utilize the future version of the international Building Code in order to establish maximum occupant loads in certain classrooms to avoid providing second exits, the following documents were reviewed: • Alternate Design Request letter dated May 14, 2007 from the Architect of Record • Letter dated May 14, 2007 from the Scriber Lake School Principal describing the student enrollment • Copy of 2006 International Building Code (IBC) Section 1004 (no State amendment to this code section) The State Building Code Council has adopted the 2006 International Building Code (effective date July 1, 2007), the City is also expected to adopt this version by the effective date. The 2006 edition of the IBC Section 1004. 1.1 Exception allows the Building Official to use the actual number of occupants in a room in order to determine the design occupant load and required.exits. The maximum number of students in any one classroom at the school is 22 students; substantially. -less than 49_ Therefore the tequesi is hereby Appt'aved .for the following classrooms: H8; 1110, H16 and H19. Maximum occupant load signs shall be posted establishing a maximum occupant load of 49 for each noted room. The request for the Staff Lounge Room H13 is denied since there are 57 staff members, please revise the plans showing a second complying exit. Sincerely, Jeannine L. Graf Building Oficial, C.B.O. • Incorporated August 11, 1890 • Sister City - Hekinan, Japan !nr- 18`Iv CITY OF EDMONDS 121 5TH AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 • FAX (425) 771-0221 Website: mvw.d.edmondsma.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineer€ng May 10, 2007 Mr. Mitch Kent, AIA Associate Mahlum Architects 71 Columbia, Suite 400 Seattle, Washington 98104 RE: Scriber Lake High School Remodel and Use of Uni-Sex Toilet Rooms VIA FACSIMILE Dear Mr. Kent, GARY HAAKENSON MAYOR ' 207 In response to your letter dated May 7, 2007 stating technically infeasible for existing toilet room upgrades please direct your attention to WAC Amendment 3409.7.9 which states, `where it is technically infeasible to alter existing toilet and bathing facilities to be accessible an accessible unisex toilet or bathing room is permitted... You have not proven that the remodeling of existing toilet rooms is technically infeasible (please refer to IBC 3402 definition of technically infeasible). Therefore the request is denied. Please revise drawings to show accessible toilet room compliance in all existing toilet room facilities. Also, since you plan on using the 20% rule (WAC 3409.6 Exception 1) for accessible upgrades the City shall require a written engineer's estimate for the total project work and contractors bids for each portion of the accessible upgrades, in order to determine compliance to the required minimum 20% upgrade.. .This should be immediately provided to the City for review. Sincerely, 6AV� Jeannine L. Graf Building Official • Incorporated August I1, 1890 • Sister City - Hekinan, Japan