20070523151704.pdfof EDS s Ef i �St. 1890 City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 77.1.0220 DATE: May 23, 2007 TO: Randal J Munson randy.munson@comcast.net FROM: Jenny Readwin, Plans Exa in RE: Plan Check # 2007-0164 Project: Classico Homes SFR Project Address: 945 Glen St. During re -review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) ok 2) ok 3) ok 4) ok 5) ok 6) ok 7) ok 8) ok 9) 5/23/07 See attached additional comments. 4/20/07 See attached additional comments. See attached structural comments from city consultant. Respond to each item in writing. Struct e Eagle Eye Consulting Engineers, P.S. irst floor PO Box 523 Second floor Olalla, WA 98359 Total hoytjeter@centurytel.net arae 360 874 0562 Total Fax 360 874 0591 To: Theresa Umbaugh Covered Porch 121 5th Avenue N Upper Floor Deck Edmonds, WA 98020 Re: Classico Homes Date: Tuesday, May 15, 2007 \ A45 Glen Street Edmonds, WA 98020 Plan Review # 2007-0164 EECE # EDM 07-07 (3) Third Letter Struct e Stated Area S.F. irst floor 2085 Second floor 1894 Total 3979 arae 785 Total 4764 orch 60 Covered Porch 88 Upper Floor Deck 12 Grand total 4924 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the .Structural requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Page 2 of 3 EECE#: EDM 07-07 (Third letter) Classico Homes STRUCTURAL COMMENTS General 1. 3. The drawings should clearly specify the requirement for the soil at the site. Nothing is specified at this time. How were the foundations system determined for this site with out this information provided? Please add this to the drawings. R401.2 The response state to see -sheet A-1.There is not any sheet Al in the set. Please submit this on response. K Sheet A-6 FOUNDATION PLAN: 2. 2. 4. EOR, please provide analysis far the foundations below the columns shown. None was submitted in the analysis to just fy the size sizes specified. Only one footing was submitted on the response. There are other footings that required analysis to be submitted not only the one location. For example the 27'X24" footing. The response is not correct for the footing analysis. When the loads are not centered on the footing the footing will also have additional bearing pressure due to the eccentricity. The footing must be checked for PIA and MIS. The response is not correct. Submit analysis for the footing to be able to support the loads as applied to the footing specified on the drawings. IBC 1801 3. AOR there appears to be no footing specified and a garage RWS wall. Please add the required information at this locatio O Sheet A-7 UPPER FLOOR/LOWER ROOF FRAMING PLAN: 4. 4. 7. When different width beam frame into a wood column a detail is required to show how the forces will be transferred. For example beam mark 7 and beam mark 8 have a width 5-1/4 and 7" respectively. Please add detail at this location to show how the required forces will be transferred. More information is required then just stating 6x6 wood columns. The revision to change the width is fine but still the drawings do not specified the required connections of the wood post to the beams. This information should be clearly added to the drawings for all post to beam connections. The response state added column beam hardware but the revised set still does not have this information added. Please add this information to the drawings or clarify where this is specified. S. S. 16. EOR, there appears to not be a complete load path to the SW 2. Shearwall number 1, as shown on sheet A8 at bedroom number 4, has no method to transfer to the exterior shear wall (SW2) at the exterior wall located at the study. Submit analysis and details to transfer this lateral force. The response states see response from Reed and associates. There was not any response in the submitted packages. Please submit this on response. The details do apply for this area as per response. Page 3 of 3 EECE#: EDM 07-07 (Third letter) Classico Homes The drawings show a SW2 above the SWI. The drawings do not show a method to transfer the force from these walls. Please clarify on the drawings. Sheet A-8 UPPER ROOF FRAMING PLAN: b. d. 18. EOR, please specify the required collector element to transfer the shear force to the interior wall at bedroom number 2. There is not method specified to transfer this force at this location. The drawings still do not show in collector elements for the interior shear walls. The response states see response from Reed and associates. There was not any response in the submitted packages. Please submit this on response. The drawing still does not show any collector element to transfer the diaphragm forces into the shear wall. There is blocking over the shear wall but there must be a collector element added to drag the force into this interior wall. This must be specified on the drawings. Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (364) 874-0562 between 8:04 a.m. and 5A0 p.m. By: Hoyt Jeter, P.E. President