20070723094446.pdfDATE: July 23, 2007
City of Edmonds
PLAN REVIEW COMMENTS
BUILDING DIVISION
(425) 771-0220
TO: Tiffany Bui
FAX: 425-640-5830
FROM: Ann Bullis, Assistant Building Official
RE: Revision to Permit #2006-0556
Project: Bui — Single Family Residence
Project Address: 16105 75th Place West
During review of the revised plans for the above noted project, it was found that the following
information, clarifications or changes are needed. Provide written responses to each comment and
where changes can be found on the plans. Please resubmit to Theresa Umbaugh, Permit
Coordinator.
1. Site Plan:
a. The revised site plan cannot contain less information than the original approved site
plan. Many items have been grayed out and did not print clearly on the revised plans,
or are missing entirely (such as labels throughout the plan, property lines, finished
grades, driveway, setback lines, easement lines, etc.). Relabel "existing rock
retaining wall" as "new" (rather than existing).
b. Clearly show original and proposed grades.
c. Provide bottom wall elevations on the plans for the new rockeries.
2. Structural calculations are required for the rockery. Rockery construction detail and calculations
must be stamped and signed by the Structural Engineer of Record. Details must be cross-
referenced to the site plans.
3. Submit Special Inspection Reports from the Geotechnical Engineer of Record for rockery
construction.
4. Submit revised Civil and Landscaping plan sheets addressing the changes made to the approved
plans.