200707241625160594.pdfDATE: July 24, 2007 TO: Jim Pensoneault 818 9th Ave South Edmonds, WA 98020 FROM: Jenny Readwin, Plans Examiner RE: Plan Check # BLD200705Y4 Project: SFR Project Address: 820 91h Avenue South During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) See attached comments from city consultant. Respond to each item in writing. 0 (5 BJY Northwest Architecture - Engineering • Planning • Government Services June 7, 2007 Return Correction Notice & Plans to City of Edmonds Only To: Kohler Associates 200 N Pacific St Suite 103 Seattle, WA 98105 Contact person: Dwayne Phone: 206-675.9100 Re: Project Description: 1 SFR With Attached Garage PLAN CK # 2007-0594 820 9T" AVE S BJY# 030731-015 Structure Level SFR Level 1 Occupancy_ Cons't. Type Area S.F R31U TYPE VB 2056/638 The above referenced project is in the process of plan review for compliance with The City of Edmonds ordinances and applicable codes (Structural, Non Structural, Energy & Ventilation). The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculationsalon with a written respons to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the ordinance, structural and energy portions of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. pE�1�!-OPM�� S�FtV1C�S 1 SHEET A3.1-2 & A2.0 1. Safety Glazing Required: Glazing in an individual fixed or operable panel that meets all of the following conditions: 7.1. Exposed area of an individual pane greater than 9 square feet 7.2. Bottom edge less than 18 inches above the floor. 7.3. Top edge greater than 36 inches above the floor. 7.4. One or more walking surfaces within 36 inches horizontally of the glazing. (R308.4) Please indicate windows requiring safety glazing on plan sheets and window schedule SHEET S2.0 1. Openings for under -floor ventilation. The minimum net area of ventilation openings shall not be less than 1 square foot for each 150 square feet of under -floor space area. (R408.1) 2694 Square Feet of under -floor area =17.96 Sq Ft of Venting area, only 14.4 Sq Ft is indicated on foundation plan. Please Clarify V STRUCTURAL COMMENTS CALCULATION 1. In seismic calculation -- page 4 of GIL. It does not appear the exterior wall weight 9psf includes stone veneer at east & south elevation (Reference to architectural sheet A3.0 & A3.1)_ Please clarify. DRAWINGS 2. General -- Provide details for the double wall plate lap splices where the plates act as diaphragm chords per IBC table 2304.9.1 item 10. 3. Sheet S 3.1. Please shows the finish grade elevation is at least 18 " min. throughout to the bottom of sub -floor joist of crawl space to be able to avoid using the preservative treated 9 %TJ1 per IBC 2304.11.2.1 4. Sheet S3.1. Please call out naturally durable woods or treated wood for the structural members that are exposed to weather, such as 2X4 @ 16 " O.C. at section B, L & M_ Per IBC 2304.11.5. 5. Sheet S 3.1. Please specify the vertical rebar in the stem wall and show standard hook in the footing per IRC R403.1.3. 6. Sheet S 3.1 & S3.2. Section shows bottom of footing below the undisturbed ground surface is less than 12 ", which is in conflict with IBC section 1805.2. Please clarify. Additional corrections may be required following receipt of corrections and additional information as requested Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact BJY at (206) 2648400 between 8.00 am and 5:00 pm. BY : Ted Chen 3