20070808134112.pdfof Eby City of Edmonds o 'D'i"0,11 PLAN REVIEW COMMENTS BUILDING DIVISION �Sr. 1s9° (425) 771-0220 DATE: August S, 2007 TO: Ken and Rani Kettel kettle@verizon.net FROM: Jenny Readwin, Plans Ex'ne RE: Plan Check # 2007-0665 Project. SFR Project Address: 21607 96' Ave W During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) Please add the following information to the site plan. ■ Add covered porch off the North side of the house at the utility room to the site plan. ■ Garage picture window needs to be on the site plan and must meet setbacks as well as included in height calculation box. ■ Specify height and material of proposed fence (Le. 6' cedar). You may redline plans or resubmit three (3) new site plans scaled no smaller than 1"=20' and one on paper no larger than S %a" x 14". 2) Provide footing drain detail on foundation sections complying with R405.1. See attached sample. 3) See attached structural comments from city consultant. Respond to each item in writing. Foundation Draina a Exam fes Footing drains are required for concrete or masonry foundation walls that retain earth and enclose habitable or useaOle space located below grade - IRC 405.1 Grade shall slope away from 6" minimum wood- fioundatiearth separation wails minimum 6 p inches within the first 10 feet, Filter membraneIM-1 1[[_ =- 4" perforated drain pipe in' washed gravel or crushed rock (minimum one sieve size larger than the opening or perforation) Habitable or useable space below grade Footing drains are required for crawlspaces if topography does not allow for.minimum 6 inch slope away from the foundation wall within the first 10 feet - IRC 409.3 6" minimum wood - earth separation Filter membrane 4" perforated drain pipe in '—"' II"" gashed gravel or crashed ' rock (miaimum.one sieve size Larger than the opening or perforation) 1:lternplhuddw,�gvmdouwi%aadxnecdC9.vsd --wo6 Crawlspace ATTACHMENT C.1 .. BJY Northwest ;,?t?c"tare • Enaineer€na - Piannina • Government Services July 23, 2007 Return Correction Notice & Plans to City of Edmonds Only To: Kettel Contact person: JoAnne Zulauf City of Edmonds 425.771.0220 x 133 Re: Project Description: 1 SFR With Attached Garage PLAN CK # 2007-0665 21607 96TH AVE W BJY# 030731-031 STORY OCCUPANCY CONST. TYPE AREA SY Garage U VB 750 1S Floor R3 VB 1569 2 Floor R3 VB 1638 Deck U VB 240 Total. Finished Area 3207 The above referenced project is in the process of plan review for compliance with The City of Edmonds ordinances and applicable codes (Structural, Non Structural, Energy & Ventilation). The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time_ SCOPE OF REVIEW The scope of this review is for the ordinance, structural and energy portions of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. 1 GENERAL COMMENTS Non Structural, Energy and Ventilation are approved STRUCTURAL COMMENTS CALCULATION 1. Please show calculation to check the maximum shear wall aspect ratios (Height -Width ratio) per IBC table 2305.3.3, The allowable shear value shall be reduced accordingly; even it meets the 3.5:1 ratio requirement after adding a concrete pier for raised -up wooden shear wall. DRAWINGS 2. Sheet 3 of 10. Detail" Shear panel at garage'. Please provide dimension of height for concrete pier. 3. Sheet 6 of 10: Detail " Shear wall schedule ". Note number 6 specifies 2X2X3116 for plate washer. 3" X 3" X 1/4 " plate washers required at each anchors bolt per IRC 2003 Sec. R602.11.1. and IBC 2006. 4. Sheet 5 of 10. Covered porch area. Provide design of deck hand railing per IBC 1607.1 (50 PLF) & 1607.1.1. (200 pounds point load) Verify fastener design considers exposure per IBC sec. 2304.9.5 & IRC Sec. 319.3. Provide detail. Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this leiter, please contact SJY at (206) 2648400 between 8:00 am and 5:00 pm. By: 4