20070829114832.pdfE D City of Edmonds 'z n i2 �i tP PLAN REVIEW COMMENTS BUILDING DIVISION t. S9 (425) 771-0220 DATE- August 29, 2007 TO: Terrance Hennig trhdesign@cablespeed.com FROM: Jenny Readwin, Plans Ex i RE: Plan Check # 2007-0804 Project: Lee Addition Project Address: 19120 83' Ave W. During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) Please add the following information to the site plan. • Reduced plot plan must be scaled no smaller than I"=20 on 8 V2" x 14" or smaller paper. • Specify if the South deck is existing or proposed. If proposed provide construction plans. • Specify datum point and elevation. You may redline plans or resubmit three (3) new site plans scaled no smaller than 1"=20' and one on paper no larger than 8 V2" x 14". 2) See attached structural comments from city consultant. Respond to each item in writing. 1'zz' BJY Northwef'; 1+6 Architecture - Engineering Planning - Government Services August 23, 2007 Return Correction Notice & Plans to City of Edmonds Only To: Theresa Re: Project Description: SFD Addition PLAN CK # 2007-0804 19120 83P-DAVE WEST BJY# 060 I STORY I OCCU CONS'TJY�E= AREA S.F The above referenced project is in the process of plan review for compliance with The City of Edmonds ordinances and applicable codes (Structural, Non Structural, Energy & Ventilation). The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time.. SCOPE OF REVIEW The scope of this review is for the ordinance, structural and energy portions of this project. All features were checked only to the extent allowed by the submittals provided, All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. I Ir 0. ARCHITgCTURAL COMMEN IS SHEET2 1 BWP notes 6d nails. Sections and details note 8d and 10d nails. Resolve. R106.1.1. SHEET3 Existing bedroom requires a smoke alarm. R313.2. I. 1 SHEET4 1. Crawl space -ventilation shall be shown on the foundation plan. Vents shall be a maximum 3'from the corners. R408.2. 2. Note embedment length of #4 rebar into existing foundation, Note both locations. RI 06. 1. 1. 3. Provide a detail of the load path from the roof deck to the foundation. The code requires details that depict the required type of construction. R301 .1. 4. Show crawl space access opening. Note that a post from the ridge beam is located at this location. R1 06. 1. 1. 5. Clarify why ABWP is noted at foundation plan. If wood cripple walls are required at the foundation plan then additional 13WP and ABWP may be required with greater hold down capacities. Detail of exterior wall framing shall show any cripple wall construction. R1 06. 1. 1. SHEET7 1. Note required roofing underlayment. R905.7.3. SHEET9 Verify that I Y2"T&G can span 5'-6" at roof overhang. Provide specifications for review. R801.2 2. Note that al I roof beams are 4x8 #2 D F - R 106. 1. 1. 3. Provide a detail for beam connections at the ridge. All connections shall be detailed. R802.2. 4. Beams shall have a positive connection at exterior walls. Detail, R801.2. SHEET 10 1. Notes call for roof trusses. Clarify. R106.1.1. 2. Note blocking requirements for vertical cedar siding. R703.4. 3. Detail roof construction. The roof diaphragm shall transfer loads into the BWP below. It is not clear how the rigid insulation is installed and where the plywood diaphragm is located. R301.1. N V 1 1.: STRUCTURAL COMMENTS DRAWINGS SHEET9 I It appears that the 4x12 SS DF. ridge beam is slightly overstressed. Provide calculations. R801.2. SHEET2 The existing exterior wall between the addition and the existing living room shall have some structural shear wall material that can resist lateral forces. Note wall material and nailing requirements. This material can be either on the exterior or the interior. R602.1 0 2. Note that the exterior rake wall shall be constructed with full height studs.R602.3. ENERGY COMMENTS 1 . Note U values for new windows on the plans. Additional corrections may be required following receipt of corrections and additional infonnation as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact BJY at (206) 264-8400 between 8:00 am and 5:00 pm. By: cz - Ted Chen 3