20071003083648.pdfSOV SDAt O ti � Sid Y t [[ f Fs r. 1890 City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: October 3, 2007 TO: Landsverk Quality Homes Lgh.inc@comcast.net FROM: Jenny Readwin, Plans Ex in RE: Plan Check # 2047-0860 Proj ect: SFR Project Address: 9007 196th Street SW During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) Please add the following information to the site plan. ■ Datum point 85' off the property point will be impossible for the building inspector to perform height verification inspection. Please choose alternate datum point and specify elevation (i.e. top of fire hydrant, ect.). ■ Clearly label covered porches. The one off the living room is covered by some working You may redline plans or resubmit three (3) new site plans scaled no smaller than 1 "=20' and one on paper no larger than 8 %2" x 14". 2) Show how island sink will be vented through the roof or with a loop vent as permitted by UPC 909.0.Air admittance valves are not permitted unless first approved by the Building Official under and alternate method per UPC 301.2. 3) See attached structural comments from city consultant. Respond to each item in writing. Eagle Eye Consulting Engineers, P.S. PO BOX 523 Olalla, WA 98359 hoyqeter@centurytel.net 360 874 0562 Fax 360 874 0591 211 To: Duane Landsverk J° ,- 21118 66th Ave. W Lynnwood, WA, WA 98037 Re: Landsverk Quality Homes, Lot 1 c .OSt Q( �ot4o5 � 9007 196TH at SW Lot 1 Edmonds, WA, WA 98020 Plan Review # 2007-0860 Structure Arca S.F. Main Floor 2968 Total 2968 Garage 726 Total 3694 Porch off living room 180 Patio/porch @ n 316 nand total 4190 9/19/2007 EECE # EDM 07-31 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the Structural requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Page 2 of 5 EECE#: EDM 07-31 Landverk Quality Homes, Lot 1 ORDNANCE COMMENTS General 1. Please note on the drawing the method to prevent water from accumulating behind the wall. R703.1 Sheet 2: Floor Plans 2. All rooms that have a closet must be considered a sleeping room. Therefore please modify the den room to meet the sleeping room requirements. For example smoke alarms and egress requirements. R313.2 and 8310 3. The furnace and water heater room is considered part of the garage since the door is not a separation. All penetration from the garage must have the opening filled with an approved material that will resist the free passage of flame and product of combustions. Please note this on the drawings. R309.1.2 Sheet 3: Foundation Plan 4. Based off the layout of the foundation system, there is not cross ventilations with at least one vent installed with -in three feet of each comer. Either modify the crawl space ventilation to use 1 over 150 or install one with -in 3 feet of each corner as required per code. 5. Please specify the required slope of the garage slab on the drawings. R309.3 Sheet 5: Roof Plan 6. It is not clear how 50% to 80% of the roof ventilation is in the upper third of the roof. Please clarify how this is met in order to use 1/300 to determine the minimum roof ventilations. R806 Sheet 6: Details STRUCTURAL COMMENTS General 7. Please add the required nailing table on the drawings. This has been modified from the 2003 code and should be added to the drawings to show the nailing that is required. Only the pertinent information that applies to this project should be clearly identified on the drawings. Table 602.3 Page 3 of 5 EECE#: EDM 07-31 Landverk Quality Homes, Lot 1 8. Please provide a key plan for the analysis of the beams. All that is noted is worse case but it is not clear how the worse case was determined. Please submit this on the response. 9. Engineer of Record (EOR), it appear the lateral design used a story height of 8 feet but the drawings specify the height is 9 feet. Please resubmit analysis with a height of 9 feet as shown on Sheet 1. 10. Please label on the drawing that the bottom chord of the trusses roust be designed for a live load of 20 PSF. IRC table 8301.5 Sheet 2: Floor Plans 11. The garage header is supporting a point load from the girder truss that has not been included in the design of this header. Please clarify on the response. 12. Please modify the header beam at the PF/S shear wall to meet the minimum depth. 4X10 does not meet these requirements. Please modify accordingly. IBC figure 2309.3.2 13. Please specify the required connection of the 4x4 post to the footing and at the top supporting the 4x8 beams. 14. EOR, please provide a detail how the 4x8 porch beam is being supported at the exterior walls. Currently there is not any method for this support. Sheet 3: Foundation Plan 15. The drawings do not show any method to connect the beam to the supporting post. A positive connection is required to be added to the drawings to prevent lateral translations. Please add this information to the drawings. 16. EOR, please submit analysis for the 4x10 crawl space beam. 17. EOR, it appear based off the roof framing and floor framing the corner footing at the family room will not support the required design loads. Submit analysis to justify. 18. EOR, please provide analysis for the wall typical footing support for the post supporting the girder truss at the perimeter wall. One side a 3000x13 footing is noted but not the other side. Analysis is required. Sheet 4: Floor Framing Plan 19. EOR, please provide a detail at the intersection of the triple joist, double joist and the girder beam at the nook area. Page 4 of 5 EECE#: EDM 07-31 Landverk Quality Homes, Lot 1 20. Please note on the drawing that the joist shall lap a minimum of 3" and must be nailed together with a minimum of 3 10D. R502.6.1 Sheet 5: Roof Plan 21. EOR, please provide a detail at the covered porch and the living room to show how this will be framed to transfer the design forces. It is not clear how this will be built based off the drawings submitted. 22. EOR, please provide a detail at the gas fireplace area. It is not clear how this area will be supported. Sheet 6: Details 23. Detail A4: EOR, please specify the required connection of the 514X4 cleats to the post and the beams. This is required to be specified on the drawings. 24. Detail A5: The code states the maximum unbalanced fills shall not exceed 4 feet. The reason for this is the soil on the passive side is resting the forces and shall not be sloped away as shown. Modify the detail to show level back fill so the maximum 4 feet is not exceeded. R404.1.4 25. Detail A5: Please specify the reinforcement for the wall shown not just the table to use. How is the contractor going to determine the classification of the soil or know what reinforcement to use? Modify the drawings accordingly. 26. Detail A: Please specify the required connection at the top of wall. The top of the wall is required to be supported to use IRC provisions. R404.1.3 27. Deck Detail: Provide analysis for the deck guard to transfer the code required forces. There is no information how this will be connected to transfer the forces. Sheet 7: S1: Structural Notes 28. EOR, please modify the shear wall required washer to be a 3x3xl/4 not 3116. The code required the washer to be a minimum thickness of .229 inches. IBC 23 05.3.11 and R602.11.1 ENERGY COMMENTS Prescriptive method used: No comment at this time VENTILATIONS AND INDOOR AIRQUALTIY COMMNETS Page 5 of 5 EECE#: EDM 07-31 Landverk Quality Homes, Lot 1 Sheet 2: Floor Plans 29. Please specify the required whole house fan size based off number of bedroom and square feet of habitable space for this house. Nothing is specified to meet the table in the code. Please add this information to the drawings. ( Please note the den room must be considered a bedroom room) 30. Please specify the required fan size in the master bathroom. Nothing is specified at this time. ( Alternative note that 50 cfm ass typical on the drawings) Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Teter at (360) 874- 0562 between 8:00 a.m. and 5:00 p.m. LO Hoyt Jeter, P.E. President