20071024153238.pdfa� Eng City of Edmonds � O PLAN REVIEW COMMENTS BUILDING DIVISION Est. i a9° (425) 771-0220 DATE: October 24, 2007 TO: Bruce Goodnight zokabear(a)aol_com FROM: Ann Bullis, Assistant Building Official RE: Plan Check: 2007-0945 Project. Cutter's Point -- Plumbing Project Address: 636 Daley Street During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Provide written responses to each comment and where changes can be found on the plans. Please resubmit to Marie Harrison, Permit Coordinator. 1. Provide drainage fixture unit calculations to verify DWV sizing (see UPC Table 7-3 and 7-5). Water supply fixture unit calcs were provided with the application, but not drainage fixture unit calcs. 2. Note the type of piping (ABS, PEX (include mfg), copper, etc). 3. Note and verify the slope of the drain/waste piping (minimum 2%). 4. Show location of 6" cleanouts at exterior of building at hookup to side sewer to coordinate with civils. 5. Will the hydronic heating be included with this application, the mechanical application, or under a separate permit application? If it will be included in this application, note whether the boilers will feed both domestic and hydronic lines, show locations of RPBAs including model number, and note whether it will be in -floor or with radiant wail heaters (or a combination of both). Provide manufacturer's installation information for the boilers. Will hydronic heat be installed in all units? #B55 city of edmonds development information Plumbing Permit Submittal Requirements PERMIT REQUIRED: A permit is required to install, alter, repair, relocate, or replace any portion of a pot4ble or waste plumbing system. Including'gas hot water tank replacement, water service line repair or replacement, propane tanks, and to install or alter gas piping_ EXEMPT WORK: The clearing of stoppages or the `repairing of leaks in drains, pipes, valves, vents or fixtures, and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes or fixtures. CODES. Uniform Plumbing Code 2006 Edition International Fuel Gas Code 2006 Edition LPG per 2001 NFPA-58 and 2002 ANSI2223.1/NFPA-54 FEE: Base fee $30 plus additional fees based on the number and type of plumbing fixtures plus $15 City surcharge fee SUBMITTAL REQUIREMENTS FOR NEW INSTALLATIONS- I- NSTALLATIONS:I_ Permit Application Form C and Plumbing Fixture Form B (attached) 2. On a scaled floor plan show the following: ® Drain, Waste and Vent piping layout; sizi o e and pi a material ® Potable water line layout, sizing an i e material Fixture unit and flow calculations to support line sizing �/�4riVl�r�r- 31 Cross connection devices are required on all direct connections to the potable water system. Specify all fixtures that require cross connection devices (i.e., ice machines, soap ejection systems, beverage dispensers, boilers, etc.) and note the make and model of each device. 4_ Indicate the location and cross connection device for premise isolation Q Manufacturer's specifications for equipment such as sump pumps, ejector pumps, water heater boosters, etc. Mnq-OT�)L 'Po5 6. Gas piping layout, sizing and pipe material, pipe sizing calculations, maximum design operating pressure and location of pressure regulators 7. For Commercial and Multifamily projects, provide Listed and Tested Fire Stopping Assemblies Revised 7/07