20071107142319.pdfCity of Edmonds O� N PLAN REVIEW COMMENTS. BUILDING DIVISION �Sr, t ago (425) 771-0220 DATE: November 7, 2007 TO: Greg and Maria Hinkel greghin@microsoft.com FROM: Jenny Readwin, Plans E4 RE: Plan Check # 2007-1014 Project: Hinkel Addition Project Address: 7517 172°6 Street SW During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) Please add the following information to the site plan. ■ Show landing outside the office exterior door. ■ Label deck as proposed You may redline plans or resubmit three (3) new site plans scaled no smaller than 1 "=20' and one on paper no larger than 8 %" x 14". 2) Overall lot slope as well as the section through the new additions exceeds 15% so a soils report is required stamped and signed by a Washington State Licensed Professional Engineer. See attached for minimum report requirements. 3) See attached structural comments from city consultant. Respond to each item in writing. Eagle Eye Consulting Engineers, P.S. PO Box 523 Olalla, WA 98359 hoytjeter@centurytel.net 360 874 0562 Fax 360 874 0591 To: Marie Harrison 121 5th Ave. N. Edmonds, WA, WA 98020 Re: Hinkle Addition 7517 172nd St. S.W. Edmonds, WA, 98026 Plan Review # 2007-1014 21 Date: October 19, 2007 EECE # EDM 07-50 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the Ordinance, Structural, V&L4QC, and Energy requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. ORDINANCE COMMENTS SHEET 7: ELEVATIONS 1. Please clarify that the windows shown at the upper floor deck will be operable, to meet egress requirements. R310.1 2. Please specify that the windows shown at the two new decks will be safety glazing. R308 Page 2 of 4 EECE#: EDM 07-50 Hinkle Addition SHEET 2: UPPER & MIDDLE FLOOR PLAN 3. Please specify the location of all required smoke alarms, per R311.2. 4. Specify that all the smoke alarms shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the individual unit. R311 5. Please show the required stair illumination and the location of the light activation at each run of stair, per R303.6. 6. Please provide deck details. From the sections on Sheet 5, it appears that the upper deck cantilevers. Please specify what kind of decking and guard rails are being provided. R106.1.1 SHEET 3: FOUNDATION PLAN/ MIDDLE FLOOR FRAMING 7. Please show locations of under floor ventilation, as required per R408. Include an analysis to show how much ventilation is required, as well as how that requirement will be satisfied. Also note how the ventilation of the existing crawl space (to the existing house) will not be adversely impacted. R408.1 and R408.2. SHEET 4: ROOF FRAMING PLAN 8. Please provide an analysis to show how much attic ventilation is required, and specify how that ventilation will be provided. R806 9. Please clarify how the construction of the new roof will not adversely impact the existing ventilation to the existing roof. It appears that some existing eave venting will be eliminated by the addition of the new roof. Please clarify. STRUCTURAL COMMENTS GENERAL 10. Please add to the drawings the Fastening Schedule from Table R602.3. 11. Please clarify where the horizontal diaphragm nailing has been specified. (I can find the wall nailing schedule, but not the horizontal nailing schedule). Sheet 2: UPPER & MIDDLE FLOOR PLAN 12. Please provide analysis for the 2x10 at 16" on center spanning 24 feet with a 5 foot cantilever. Page 3 of 4 EECE#: EDM 07-50 Hinkle Addition Sheet 3: FOUNDATION PLAN/ MIDDLE FLOOR FRAMING 13. Please specify the required connection of the 3-1/2x9 and 8-3/4x9 Glulam beams. 14. Please specify all the required post to beam connections on the drawings. 15. Provide analysis for the 4x6 ledger supporting the floor joists. Per check analysis, it appears that the required design forces will not be resisted. 16. Please provide detail and analysis for the ledger supporting the deck framing. 17. Please specify the size of the footing supporting the 3-1/8x10-112 Glulam. 18. Please specify the required post supporting the 3-1/8x10-112 Glulam. 19. Please specify, the required connection of the post to the 3-1/8x10-1/2 Glulam. 20. Please specify the required connection of the post (supporting the 3-118x10-1/2 Glulam) to the footing. 21. Please provide details for the required guards at the new deck. Table R301.5 Sheet 4: ROOF FRAMING PLAN 22. Please specify the required connection of the stair stringer to the supporting structure. 23. Please specify the required connection of the 2x10 hip rafters to the supporting structure. Sheet 5: BUT DING SECTIONS 24. Please specify the required connection of the new roof ledgers to the existing framing. 25. Per the location of the footing at grade (as drawn in the building section), it appears there won't be enough distance to prevent shallow failure. Please clarify. R403.1.7.1 26. Please provide analysis for the additional load being applied to the top of the existing will not overstress the existing soil below. Page 4 of 4 EECE#: EDM 07-50 Hinkle Addition SHEET 6: FRAMING ELEVATIONS 27. Please specify the required connection of the engineered wood joists to the supporting members. 28. Please specify the required connection of the roof trusses to the supporting walls. Nothing is specified at this time. ENERGY COMMENTS SHEET 1: 29. Please update the window specifications to meet the minimum standards of the current 2006 Energy Code. The U -value shall be .35, not .40, as currently state. Washington State Energy Code Table 6-1 SHEET 5: 30. Please note the required vapor barrier separating the conditioned space from the unconditioned space. 502.1.6.2 VENTILATION & INDOOR AIR QUALITY CODE (V&IAQC) GENERAL: 31. Please clarify the location and size of the Whole House fan. Additions greater than 500 square feet of conditioned floor area are not exempt from meeting whole house ventilation WSV&IAQC 101.3.1.1 Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (360) 874- 0562 between 8:00 a.m. and 5:00 p.m. Hoyt Jeter, P.E. President SOILS INVESTIGATION AND/OR REPORT (Cont.) The classification of bearing soil at the site .must be determined and called out on the plans. The following information from IRC Table R401.4.1, will assist individuals in determining the soil classification of the building site. The Building Official may require this classification to be made by a Washington State licensed Geotechnical Engineer or Engineering Geologist in a written report when soils are not adaptable to conventional spread footings or if allowable foundation and lateral pressures do not meet the values set' forth in the table below. The allowable foundation . and lateral pressures may not exceed the values in this table, unless data to substantiate the use of higher values is submitted. Sidehill or steep slope construction IS NOT considered conventional construction and soils reports are required for lots with 15% or more slope, unless determined unnecessary by the Building Official. For more specific and technical information on soil capacity, foundation design and construction components, refer to 113C Chapter 18 an C Chapter 4 or contact a professional engineer. TABLE R401A.1 PRESUMPTIVE Lorca -REARING VALUES OF 2a0t;IN0ATr0v N4ATFR1AtAl For Sl- i pound per square toot= 0.0479 kNlm2_ a. When soil tests are required by Section 8401.4, the allowable bearing capacities of the soil shall be part of the recommendations. b. Where the building official determines that in-place soils with an allowable bearing capacity of less than L,SOO psf are likely to be present at the site, tate allowable bearing capacity shall be determined by a soils investigation. When soils reports are required, they shall include the following: 1. A plot plan showing the location of test borings and/or excavations. 2. A complete record of the soil samples. 3. A record of the soils profile. 4. Elevation of the water table, if encountered. 5. Recommendations for foundation type and design criteria, including but not limited to: bearing capacity of natural or compacted soil; provisions to mitigate the effects of expansive soils; relitigation of the effects of liquefaction, differential settlement an carrying soil strength, the effects of adjacent loads, and foundation drainage. 5. Expected total and differential settlement. 7. Pile and pier foundation information in accordance with IBC Section 1808-2.2. 8. Special design and construction provisions for footings or foundations founded on expansive soils, as necessary. 9. Compacted fill material properties and testing in accordance with IBC Section 1803.5. NOTE: Report recommendations shall be incorporated into the foundation design 4. DRAINAGE PLAN (See Handout #E72) Development of over 2,000 square feet of new impervious area since July 1977 requires an on-site drainage. system- Impervious area includes: building pad with eave overhangs, paved or graveled areas, solid surface decks, patios, walkways, breezeways, awnings, accessory structures, sidewalks, and driveways. Submit three (3) -drainage plans, scaled 1"--20', showing all impervious area with square footages as well as the location of the proposed drainage detention system. Attach three (3) copies of the drainage worksheet (See Handout #E72). Note: The plan must provide for temporary and permanent erosion control and must include footing drain details. 3 L \TEiviP1€iEfILDINGWIANDOUT ICODESISFR 1373.DOC Revised 5106 lGo:w-Iil�Alurrc PRESSURE CLASS OF MATEPUAL uuuds per square foot Crystallitte bedrock 17,000 Sedimentary and foliated rock 4,900 Sandy gravel and/or gravel GW and GP) 3,000 Sand, silty sand, clayey sand, silty gravel and clayey gravel 5W, SP, Slbf, SC, GM and CC) 2,000 Clay, sandy clay, silty clay, clayey silt, siltand sandy silt CL ML, M1-1 and CH 1,500° For Sl- i pound per square toot= 0.0479 kNlm2_ a. When soil tests are required by Section 8401.4, the allowable bearing capacities of the soil shall be part of the recommendations. b. Where the building official determines that in-place soils with an allowable bearing capacity of less than L,SOO psf are likely to be present at the site, tate allowable bearing capacity shall be determined by a soils investigation. When soils reports are required, they shall include the following: 1. A plot plan showing the location of test borings and/or excavations. 2. A complete record of the soil samples. 3. A record of the soils profile. 4. Elevation of the water table, if encountered. 5. Recommendations for foundation type and design criteria, including but not limited to: bearing capacity of natural or compacted soil; provisions to mitigate the effects of expansive soils; relitigation of the effects of liquefaction, differential settlement an carrying soil strength, the effects of adjacent loads, and foundation drainage. 5. Expected total and differential settlement. 7. Pile and pier foundation information in accordance with IBC Section 1808-2.2. 8. Special design and construction provisions for footings or foundations founded on expansive soils, as necessary. 9. Compacted fill material properties and testing in accordance with IBC Section 1803.5. NOTE: Report recommendations shall be incorporated into the foundation design 4. DRAINAGE PLAN (See Handout #E72) Development of over 2,000 square feet of new impervious area since July 1977 requires an on-site drainage. system- Impervious area includes: building pad with eave overhangs, paved or graveled areas, solid surface decks, patios, walkways, breezeways, awnings, accessory structures, sidewalks, and driveways. Submit three (3) -drainage plans, scaled 1"--20', showing all impervious area with square footages as well as the location of the proposed drainage detention system. Attach three (3) copies of the drainage worksheet (See Handout #E72). Note: The plan must provide for temporary and permanent erosion control and must include footing drain details. 3 L \TEiviP1€iEfILDINGWIANDOUT ICODESISFR 1373.DOC Revised 5106