20071127100125.pdfflF City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION i (425) 771-0220 ES t. 189 DATE: November 27, 2007 TO: Sara Winters 1138 6th Ave S Edmonds, WA 98020 FROM: Jenny Readwin, Plans E amin RE: Plan Check # 2007-1148 Project: Interior Remodel Project Address: 1138 6t" Ave S. During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) An additional smoke detector is required outside bedroom 1. note on plans. 2) Label egress window in bedroom 1. 3) New French door addition to bedroom 2 does not meet conventional wall bracing of IRC. Revise to meet conventional or provide lateral calculations stamped and signed by a Washington State Licensed Professional Engineer. 4) Provide general roof framing plan to show that all walls being removed are non-bearing. I see existing rafter location in Bedroom 2 but what happens over the bathrooms and bedroom 1? If any new beams are proposed show size and location on the plans as well as clearly show how all loads are carried to bearing and provide beam calculations.