20071219 Valhalla Foundation Only.pdf
DATE: January 9, 2008
TO: Tony Shapiro
tony@adshapiro.com
FROM: Jeanie McConnell, Engineering Program Manager
RE: Plan Check #: 20071219
Project: Valhalla Mixed Use Foundation Only
Project Address: 23020 Edmonds Way
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Please redline plans or submit three (3) sets of revised
plans/documents with a written response to each of the items below to Marie Harrison.
City of Edmonds handouts and standard details can be referenced on the City website under
Development Services Department, Engineering Division.
1.A1.1 Site Plan submitted with this permit application indicates placement ecology blocks with
the west face a minimum of 2 away from the existing edge of pavement. Please provide a cross
section that clearly shows:
nd
Existing 232 travel lanes centerline, fog line, edge of pavement.
o
Placement of ecology blocks in relationship to the travel lane. A minimum 12 travel lane
o
and 2 shy distance shall be maintained.
Subgrade requirements, per Engineer of Record, for placement of ecology blocks. As stated,
o
they will not be placed on the existing asphalt surface.
nd
Maximum slope allowed, per EOR, between 232 and the foundation.
o
Please contact me at 425-771-0220 or by e-mail at mcconnell@ci.edmonds.wa.us if you have
specific questions regarding these plan corrections.