2008-0031 Michel7Unit3.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: December 17, 2008 TO: Dwight McGrew Email: michelbz@nwlink.com FROM: Leif Bjorback, Assistant Building Official RE: Plan Check # 2008-0031 Project: Michel 7 Unit Condominium Project Address: 316 Walnut Street Below are combined comments from the City’s plan review consultant and myself. Provide written responses to each comment and where changes can be found on the plans. Please resubmit to Theresa Umbaugh, Permit Coordinator. Applicant responses to previous comment letter are in italics. 1.Previous item 3: See sheet A14, detail R and Sheet A13, Detail V. The details provided are satisfactory. Please provide callouts on the appropriate sheet to clearly show locations where the details apply. 2.Previous item 4: See sheet A14, detail R and Sheet A13, Detail V. The details provided are satisfactory. Please provide callouts on the appropriate sheet to clearly show locations where the details apply. 3.Previous item 6: See Sheet A2, an area of refuge has been provided. Sheet A2 does not show an area of refuge as noted, but it does appear on Sheet A3. IBC 1007.1 requires that each required means of egress be accessible; thus, there should be st an area of refuge at each required exit, including those at each floor level other than the 1 floor. (A previous conversation with the Building Official clarified that only one exit is required from each dwelling unit.) Please show on the plans, for each location, the following requirements from Section 1007.6, at a minimum: One 30” by 48” wheelchair space located within the stairwell or other smokeproof · enclosure. Such wheelchair spaces shall not reduce the required means of egress width. A two-way communication system including both audible and visual signals. Indicate · where the central control point is located and how it will be monitored. The location of the central control point shall be approved by the fire department. Instructions for the use of the area as stated in Section 1007.6.4. · Visual and tactile signage complying with ICC A117.1 identifying the area of refuge. · Signage at the elevator and other non-accessible exits indicating the location of the · accessible means of egress. At the west man-door exit at the garage level, you will need to show an “exterior area for assisted rescue” per 1007.8. 4. Previous item 7: Please change the notes on A4 and A5 to indicate the distance between exits to be 1/3 of the overall diagonal since the building is sprinklered. By “Elevator distance, do you mean “exit separation distance”? IBC 1015.2.1 exception 2. 5. Previous item 9: Please show on sheet P2 that the series of 42” landings provides a minimum 36” wide continuous walkway. Ordinance Comments 1.Previous item 1: Response states P-1 will be stamped. Neither P-1 nor P-2 have been stamped. Also, there are a number of ‘A’ pages that have not been stamped. Sheet A14 2.Previous item 19: On Detail B/A15 please show 2 layers of drywall within the lined joist bays to match the number of layers at the ceiling. Structural 3.Previous item 22: EOR, please stamp and sign the design calcs provided for the dead weight of the floors. Sheet A7 and A14 4.Previous items 23-26: These items were not addressed. Sheet S-3 5.Previous item 32: See detail 2/S-2.1& 3/S-2.1.The details provided are satisfactory. Please provide callouts on the appropriate sheet to clearly show locations where the details apply. 6.Previous item 33: See detail 3/S-2.1& 3/S-2.2. The details provided are satisfactory. Please provide callouts on the appropriate sheet to clearly show locations where the details apply. Sheet S-4 7.Previous item 36: Please provide gravity analysis for deck ledger as shown on S-2.4. The stated spacing of 5/8” through bolts at 16” o.c. will not work. Also, please reference the detail on Sheet A10 or S-5 or both. Sheet S-5 8.Previous item 39: Detail 1/S-2.2 can be used. The detail provided is satisfactory. Please provide callouts on the appropriate sheet to clearly show locations where the details apply. Sheet S-6 9.Previous item 40: See details 3/S-2.3 & 4/S-2.3. The details provided are satisfactory. Please provide callouts on the appropriate sheet to clearly show locations where the details apply. 10.Previous item 41: Again, see detail 10/S-2.3. The detail provided is satisfactory. Please provide callouts on the appropriate sheet to clearly show locations where the details apply. General 11.Please submit two completed Special Inspection Agreement forms, one for structural and the other for the remaining geotechnical special inspections. Page 2 of 2