20080107151830.pdfo� Ego City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION gst 1$90 (425) 771-0220 DATE: January 7, 2008 TO: LIU and Associates, Inc. J. S. Liu, P.E. 19213 Kenlake Place NE Kenmore, WA 98028 FROM: Jenny Readwin, Plans Ex n ' f RE: Permit # 2007-0566 Project. Crabb Revision Project Address: 835 Maple Street During re -review of the above noted revision, it was found that the following information, corrections, or clarifications are needed. 1) 1/7/07 See attached additional comments. See attached comments from City's Structural Consultant. Eagle Eye Consulting Engineers, P.S. PO Box 523 Olalla, WA 98359 hoytjeter@centurytel.net 360 874 0562 Fax 360 874 0591 To: Theresa Umbaugh 121 5th Ave N Edmonds, WA 98020 Re: Crabb Residence Retaining wall 835 Maple Street Edmonds, WA 98020 Plan Review # 2007-0566 EECE # EDM 07-87 (2) Plan review number 02 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the Structural requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. STRUCTURAL COMMENTS General 1. New design analysis for the 12' high wall states no good for vertical installations. The internal stability exceeds the minimum code safety factor of 1.5. Revise analysis or drawing to not exceed the 1.5 safety factor as required for retaining walls. Each segment of the wall shall meet the minimum code requirements. IBC 1806. 2. New design analysis state different type to be used for the geogrid. Please clarify that the MIRAGRID 7XT meets the types required. It is not clear based off the information's submitted. Page 2 of 2 Plan Review Number 02 EECE#: EDM 07-87 Crabb Residence 2007-0566 Sheet SW -1 3. .l. The analysis submitted required the wall to be battered back 4 degrees but the drawings note vertical not battered. This is very important. This wall acts as a gravity wall with geogrid resisting the horizontal soil pressure. If the wall is not battered back then the wall will tend to also add to the horizontal pressure if the front settles just a small amount. Please modify accordingly. New analysis submitted for vertical install block wall show the internal stability will not meet the minimum safety factor of 1.5. Please modify accordingly and resubmit. IBC 1806 4. New analysis submitted state the base reinforcement length shall be 10 feet measure from the face of the wall but the drawings state 4' measure from the key. Please modify the drawings to show the 10 feet will be met or submit new analysis with the correct length as specified on the drawings. Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (360) 874-0562 between 8:00 a.m. and 5:00 p.m. By: Hoyt Jeter, P.E. President