Loading...
20080124082327.pdfo� EDo City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION �'sr. g90 (425) 771-0220 DATE: January 24, 2008 TO: Joe Myers joemyersconstraction@comcast.net FROM: Jenny Readwin, Plans Exin RE: Plan Check # 2008-0023 i/ Project: Claire Rhodes Trust Interior Remodel Project Address: 8723 Talbot Rd. During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the items below to a Permit Coordinator. 1) Please add the following information to the site plan. ■ Swimming pools must be completely surrounded by a substantial fence at least six feet in height, no openings greater than 2" and self=closing, self -latching gates with inside lock inaccessible to children is required. Per ECDC19.00.005(C)(7)(C) any swimming pool not presently fenced complying with these requirements must be upgraded. Please show complying fence on the site plan and specify if existing or proposed. You may redline plans or resubmit three (3) new site plans scaled no smaller than 1"=20' and one on paper no larger than 8 %2" x 14". 2) Clearly note on the floor plan which windows are existing and which ones are to be replaced and if new or larger than what was is currently there. Also, note all safety glazed and egress windows (Le. safety glazing required for window next to foyer door, master bathroom tub, egress out of bedroom 4, etc.). 3) Gas fireplace in the master bedroom must be direct vent. Note on plans. 4) ,Show minimum 3' hard surface landing at each exterior door. 5) An additional smoke detector is required outside the master and bedroom 2. Note on plans. 6) Note garage/dwelling separation on plans. Minimum V2" sheetrock required on garage side of wall and 5/8" type X on the ceiling when there is habitable space above and minimum 20 minute rated or 13/8" solid core door. 7) Provide section detail at the stair showing how the minimum 6'-8" headroom will be met. Also, specify if the stairs them selves will be replaced. If so, show rise, run„ etc. 8) It appears that there will be a site built shower. Provide shower pan construction detail including materials, drain, slope, etc. 9) Provide manufactures installation instructions for proposed sauna. 10) Cross reference all details to their location on the plans. Cross out any details that do not apply to this house. 11) Provide complete roof and floor framing as well as foundation plan to clearly show how all loads are carried to bearing. On these plans clearly show what is existing and what is proposed. 12) Provide a section detail from the foundation through the roof at the living room area where the floor level is being lowered. 13) Provide calculation for 18" footing under post supporting 5 118" x 10 %2" GLB (5100#) or revise to 24"x24"x 12". 14) There is a point load on the 5 1/8" x 10 %2" GLB per the calcs and the plans. Please clarify where that point load is coming from (beam above?). If there is a new beam above specify size and provide beam calculation. 15) On the basement plan there is a post shown just inside the foundation wall for the proposed 6x10 beam. Please clarify how this is supported (new footing?). 16) Clarify how the loads from the 4x10 master bedroom door header are carried to bearing. Page 2 of 2