2008-0139_GavrilovichSFR.pdf CE ITY OF DMONDS th 121 5 Avenue North • Edmonds, WA 98020 Phone: 425.771.0220 • Fax: 425.771.0221 • Web: www.ci.edmonds.wa.us DSD: P•E•B EVELOPMENTERVICESEPARTMENTLANNINGNGINEERINGUILDING March 25, 2008 Stacy Smith Smith Land Development Services st 6428 221 Avenue NE Granite Falls WA 98252 Phone: 425.238.6324 | Fax: 360.691.4857 | Email: stacy.smith@hughes.net th RE: BLD-2008-0136 – Gavrilovich SFR @ 6904 174 Street SW (RS-12 Zone) Dear Applicant, I have reviewed the above building permit application for the Planning Division and it was found that the following information, corrections, or clarifications will need to be addressed before review can continue. If you have any questions, please do not hesitate to contact me. I look forward to working with you on this project. Please provide a written response to the items mentioned below… th 1.Address: Please revise the address on the site plan, it should be 6904 174 Street SW. 2.Patios: Are any patios proposed? If so, please include them on the site plan. 3.Grading: Please confirm the grading estimate. If either 500 cubic yards of cut or fill is proposed, review under the State Environmental Policy Act (SEPA) is required – please contact me immediately to go over the requirements if you think you might be close. 4.Height Calculations: Please take another look at the height calculations provided on the site plan, confirm that they are taken from original grade, and respond to the following items. If revisions are necessary, please revise both the site plan and the elevations (sheet 4). a. When you add up the four height elevations provided in the Height Calculation box, the “Average Grade” is off, which throws off the rest of the math. b. Point “A” is shown as 427 but it also looks close to the 422 contour. c. Point “B” is shown as 438 but it also looks close to the 428 contour. 5.Rockery Height: Please confirm the rockery height as measured from top of rock to original grade. The Planning Division calculates height based on original grade. Structures (anything over three feet in height) are required to meet setbacks, so the rockery height within the setback area cannot exceed three feet as measured from top of rock to original grade. Please clarify rockery height on the site plan in relation to original grade. Sincerely, Gina Coccia, Associate Planner Phone: 425.771.0220, x 1778 | Email: coccia@ci.edmonds.wa.us Page 1 of 1 Note: Please provide a written response to the items mentioned above. Also, please redline your plans to reflect any changes – or, if you are submitting new plans, please submit three site plans (one must be reduced size) and two sets of the changed pages of the plans. Please make all submittals to the Development Services Permit Coordinator (Theresa Umbaugh) Monday through Friday, 8am-4pm (except Wednesdays). All Edmonds Community Development Code (ECDC) citations can be found on the City of Edmonds website: www.ci.edmonds.wa.us.