20080226135227.pdfo Eby City of Edmonds
PLAN REVIEW COMMENTS
BUILDING DIVISION
Fey. 1g90 (425) 771-0220
DATE: February 26, 2008
TO: Duane Landsverk
duane@lgh.inc.com
FROM: Jenny Readwin, Plans xarni
RE: Permit # 2007-0859
Project: Framing Revision
Project Address: 9007 196'' Street SW
During re -review of the above noted revision, it was found that the following information,
corrections, or clarifications are needed.
1) ok
2) 2126/08 Calculations submitted call out a 4x10 header for the upper floor windows and
calculation is for a 6' span. Rec Room window on the plans is 8'. Please provide calculation
for 4x10 header with 8' span. Also, calculation for garage door header below (5118"x 13
112" GLB) does not appear to account for the point load from 4x10 above. Please provide
calculation including point loads. Now that the upper floor roof has changed direction please
specify size and provide calculations for the stair door header and East wall windows as well as
calculations for the garage door headers with new point loads from above.