Loading...
20080227115648.pdfob City of Edmonds }w}:?sā€ž`:`ā€ž. PLAN REVIEW COMMENTS - BUILDING DIVISION st, i s9° (425) 771-0220 DATE: February 27, 2008 TO: Joe Myers joemyersconstraction@comeast.com FROM: Jenny Readwin, Plans Eaurin RE: Permit # 2008-0026 Project: Revision Project Address: 8723 Talbot Rd. During review of the above noted revision, it was found that the following information, corrections, or clarifications are needed. 1) Please revise building section on sheet 2 to match actual conditions (i.e. footing supporting 4x4 post at the existing foundation wall, direction of floor joist, etc.). 2) 6x10 beam for crawl space access does not reflect actual construction. The existing foundation all at this location, per my site visit, was about 2'-3' high and was all open into the crawlspace area. Please show beam for this area to completely support the floor joist and provide beam. calculation. 3) Please show 2x10 floor joists extending all the way to the 4x10 at the fireplace. 4) Plans show 4x10 at the fireplace between the two footings but how will the floor joists be supported on the other sides of that beam? If the beam extends to the exterior wall and to the beam past the furnace please show it as well as how it is carried to bearing at each end (i.e. hangers at the furnace side and post and footing the other). 5) For the 6x10 in the middle please show how it extends or how the floor joists are supported by the water heater. If beam extends and hangs off the other beam please specify hanger. 6) Please specify size of the beam that runs the same direction as the floor joist near the storage area and provide calculation including point loads if the 6x10 and 4x10 beams are hanging from them.