20080418094150.pdfEagle Eye Consulting Engineers, P.S. PO Box 523 1A N11L Olalla, WA 98359 , hoytjeter@centurytel. net 360 874 0562 Fax 360 874 0591 To: Marie Harrison 121 5th Ave N Edmonds, WA 98020 Re: Lovell Residence 7425 Braemar Drive Edmonds, WA 98020 Plan Review # 2008-0258 EECE # EDM 08-29 Plan review number OI Structure Stated Area S.F. Existing Main Floor 2220 New Upper Floor 876 Total 3096 xisting Garage 790 otal `886 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the Ordinance, Structural, V&IAQC and Energy requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. ORDINANCE COMMENTS l General 1. Please clarify on the drawings the required roof ventilations. I was unable to determine this from the drawings. R806 Page 2 of 5 Plan Review Number 01 EECE#: EDM 08-29 Lovell Residence 2008-0258 2. Please provide the required attic access size & location on the drawings. It was not clear where this information's is specified. R807.1. 3. Architect of Record (AOR), please specify the locations of the roof drains and their required size. It was not clear where this information was specified on the drawings. R 903.4 4. Please clarify if there will be a washer and dryer installed in this house. This is important to make sure the dryer is properly vented to the exterior. M1502.2 /�/ Sheet A-1 Existing Plan .rS �'rt/� Z'Jr lfA�� ' 5. Please specify the required stair illumination on the drawings. R303.6 6. Please specify the required light activation at the bottom of the stairs, per R303.6.1. 7. Usable space under stairways shall have the walls and soffits on the enclosed side protected with a minimum of 1/2 -Gypsum. There is a door shown from the Reading room that will have useable space under the stairs. Please add this to the drawings. R311.2.2 8. Please provide a handrail detail for the new stairs. R311.5.6.2. 1/taut4k ft401- 0"I// 9. Please clarify the locations of the smoke alarm on this level. One is required on each level. R313.2 item 3 10. Please clarify how the hot water tank will be vented to the exterior with the new additions. Sheet A-2 Second Floor Edition/ South Elevation 11. Please specify the required smoke alarm in the sleeping rooms. R313 12. AOR please specify the hot water tanks shall be strapped to resist lateral displacement as required per M1307.2. 13. Please clarify how the new window will meet the egress requirements per code. Please modify the drawings accordingly. R310 14. Please add guard details for the porch off the upper floor bedrooms to show code compliance. R312 15. Please specify the required light activation at the top of the stairs, per R303.6.1. Page 3 of 5 Plan Review Number 01 EECE#: EDM 08-29 Lovell Residence 2008-0258 Sheet A-4 North and East Elevations 16. Please specify that the chimney shall extend a minimum of 2 feet above any combustible material within 10 feet measured horizontally. Table R1003.1 Sheet 10 of 14 Typical Garage Foundation 17. Crawl space ventilation shall be a maximum of 3' from the comer. R408.2. Sheet E-1 Electrical Plan and Notes 18. Please note on the drawings that the smoke alarms shall be hot-wired with battery back-up. R313.2 STRUCTURAL COMMENTS General — %VVI& �ndwt�•�- Pl�'^..rc•r/�d yg �� 19. Engineer of Record (EOR), please specify the required anchorage of the truss to the supporting structures. The IBC required the register design professional to specify this. IBC 2303.4.1.6 20. AOR, please note on the drawings that the bottom chord for the truss shall be design for a live load of 20 psf. IBC table 1607.1 R301.5 21. Please specify the nailing of floor diaphragm. Table IRC 503.2.1.1(1) Sheet A-4 North and East Elevations 22. Please clarify on the drawings what is supporting the covered deck framing. It was not clear the vertical support for this area based off the submitted drawings. Please modify showing the post, girders, connections, etc in order to complete the review. ,Sheet 10 of 14 Typical Garage Foundation 23. There is no information for the attachment of the deck ledger. Please add this information to the drawing. R502.2.2 Sheet S-1 Floor Framing Plan and Notes 24. Please specify the required connection of the floor joist to the supporting beams. 25. Sections BB: Please specify the required new strap noted in this details. Page 4 of 5 Plan Review Number 01 EECE#: EDM 08-29 Lovell Residence 2008-0258 26. Section AA and BB: Please specify the required connection of the roof overhang. All this is noted is schematically the framing with out any information's for the member size, connections, etc. Please modify accordingly. 27. EOR, please provide analysis for the existing beam to support the floor framing and the roof framing above. Based off the span and assuming ET species it appear the beam will not support the design loads. Submit analysis to justify. (This also should include the post. 28. Please provide a detail at the new second floor wall bearing on the exiting joist. It is not clear how this will be constructed based off the drawings submitted. Sheet S-2 Existing Roof -Part Plan 29. Note 2: Please specify on the drawings where this note shall apply. All that is noted as required but the information where this shall be used should be specified. 30. Note 3: Please specify where this shall be used. All that is note where it is appropriate. The design drawings should clearly note where this shall be used in order to complete the review. Sheet S-3 Structural Details 31. Please modify the shear wall schedule to clear note single 3X for SW -3. Double 2x are not approved by the code for nails spacing of 2" OIC. IBC 2306.4.1 footnote e 32. Please add to the drawing the required collector elements for the interior shear wall. This is required to collect the horizontal diaphragm forces and drag it into the vertical shear wall. Please modify accordingly. 33. EOR, there appear to be no vertical lateral resisting for the cantilever floor system over the existing porch. It is not clear in the analysis how the was accounted for. This is for grid line A in the analysis submitted. Please clarify in the analysis and on the drawings how the horizontal lateral forces will be resisted based off this layout. VENTILATION & INDOOR AIR QUALITY CONTROL COMMENTS General 34. Since more than 500 square feet is being added to this structure, the whole house fan must be updated. Please modify accordingly. WSV&IAQC 101.3.1.1 Sheet E-1 Electrical Plan and Notes Page 5 of 5 Plan Review Number 01 EECE#: EDM 08-29 Lovell Residence 2008-0258 35. Please specify the required exhaust fan to use for the bathrooms. 36. Please specify the required exhaust fan to use at the furnace room. ENERGY COMMENTS General 37. Please submit analysis for how 19% of the glazing is being met as noted for the additions. Sheet A-2 Second Floor Edition/ South Elevation 38. Please specify the U value for the new window being added to this structure. It appear this is not noted on the drawings. Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (360) 874- 0562 between 8:00 a.m. and 5:00 p.m. Hoyt Jeter, P.E. President