Loading...
20080724130706.pdfr Plan Check # Date Project Name/Address "A) Contact Contact Person/Address_ VIAL w) Department: Building Engineering ❑ Planning ❑ Fire ❑ Public Works ❑ Reviewer �1_ - i_( �� irs . �� � rte. IJI�;� ■L%V d►. 1• �Nrfla��s/J ■L �l / �� ♦`!J 1�r� is Submit 2 sets of revised plans/documents to the Permit Coordinator. ❑ Corrections may be made by red lining plans/documents on file with the City. DATE FAXED (Attach fax transmittal) PAGE / OF 4— Eagle Eye Consulting Engineers, P.S. PO Box 523 Olalla, WA 98359 hoytjeter@centurytel.net 360 874 0562 Fax 360 874 0591 To: Linda Thornquist 121 5"' Ave N Edmonds, WA 98020 Re: Rachford Deck Addition 7815 175'x' St SW Edmonds, WA 98020 Plan Review # 2008-0571 PIan review number Qt Existing Deck 147 New Deck 146 Total 293 11;fie J U L 2 3 200 BUILDING DEPT. EECE # EDM 08-66 The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes. The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for the Structural, Ordinance, V&IAQC, Energy requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Page 2 of 3 Plan Review Number 01 EECE#: EDM 08-66 Ratchford Deck Addition 2008-0571 ORDINANCE COMMENTS General 1. Please specify the required protection of the fasteners in contact with treated lumber. R319.3 Sheet 1/1 Main Floor Plan, Site Plan, East Elevation, North Elevation 2. Please clarify the flashing requirement between he deck and the main house. Nothing is specified at this time. R703.8 Sheet 1 of 1 Site Plan 3. Please specify the distance the deck is away for the property line. The text appears to be erased during printing. R302 STRUCTURAL COMMENTS General 4. Without new bracing, X -bracing there is no way to transfer the lateral forces of the new deck. Please submit lateral analysis of the new deck or add the required lateral bracing for the deck. Sheet 1 of 1 Site Plan 5. The drawing shows the deck framing footings being installed on a sloped site. There is not enough lateral resistance with only a 12" embedment. Please increase the depth of the footing into the soils to resist lateral forces. Sheet 111 Main Floor Plan, Site Plan, East Elevation, North Elevation 6. Frost line depth requirements for the city of Edmonds are 18". The footing must be placed at this depth. The drawings state 12". Please modify accordingly. IRC table R301.2 7. Please specify the required joist hanger that will be used to support the joist. All that is noted is joist hanger. 8. Please submit analysis of the 1/2 -diameter lag screw @ 12" O/C to support the design loads. Per check analysis, the forces will not be supported. NDS table 1Ij. Page 3 of 3 Plan Review Number 01 EECE#: EDM 08-66 Ratchford Deck Addition 2008-0571 9. Please specify the required attachment of the deck joist to the supporting beams for lateral support of the supporting beams under bending loads. A positive connection of the joist is required at these locations. VENTILATION AND INDOOR AIR QUALITY CONTROL COMMENTS Not applicable for this permit ENERGY COMMENTS Not applicable for this permit Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (360) 874- 0562 between 8:00 a.m. and 5.00 p.m. By: Hoyt Jeter, P.E. President