20081027081022.pdfInc 15911 CITY OF EDMONDS 121 STH AVENUE NORTH • EDMONDS. WA 95020 • {425} 771-0220 • FAX (425) 771-0221 Website' www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering October 24, 2008 David and Ji Kim 7414 181St Place SW Edmonds, WA 98026 GARY HAAKENSON MAYOR sent via e-mail at David Kim's request RE: Demolition of Deck at 7414 181St Place SW, Edmonds Dear Mr. Kim, This letter is being sent as a follow-up to our phone conversation this morning regarding your statement that the exterior wall of your house is sagging due to the demolition of your deck which was done without first obtaining a building permit. You said that originally you thought the deck was designed as a cantilever, but now you are thinking it is not. As 1 stated to you on the phone, immediately contact your Structural Engineer to evaluate the structure for emergency temporary shoring requirements. Any work deemed an emergency by the Structural Engineer shall be immediately implemented and special inspection by the engineer for such work is required. Provide copies of the engineer's evaluation report and special inspection reports of the emergency shoring installation to the City by Thursday, October 29, 2008 via fax to 425-771-0221 or email to bullisLaci.edmonds.wa.us. Also as discussed on the phone, your designer, Mr. Brek, is scheduled to meet with Leif Bjorback, Assistant Building Official regarding the outstanding pian review comments that must still be addressed. Please see the attached comments and forward them to your designer for the meeting. Your structural engineer must still address item #1, while your designer should be able to address all other items. If you have any questions, please contact me at 425-771-0220. Sincerely, *A -- Ann Bullis, CBO Building Official • Incorporated August 11, 1890 • Sister City - Hekinan, Japan of ED/y City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION g90 (425) 771-0220 DATE: October 23, 2008 TO: David Kim FROM: Leif Bjorback, Assistant Building Official RE: Pian Check: 2008-0033 Review 93 Project: Kim Deck Project Address: 7414 1815` PI SW During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a Permit Coordinator. Redlining of the current set of plans is permitted provided that any structural changes are initialed and dated by the structural engineer. 1. Previous item 1: The attachment of the ledger to the existing upper floor cantilever rim joist is considered unconventional construction. As previously requested, provide structural calculations stamped and signed by the structural engineer for this ledger detail. Also, part of the "New Ledger Connection/Detail" is unreadable on the plans. 2. Previous item 8: The dimension of the opening from the deck surface to the bottom of the guardrail cannot exceed 4". Plans show 6". Please revise. 3. Previous item 9: Provide manufacturer's installation instructions and loading information for the guardrail. 4. The engineering dated 10/7/08 calls for the deck joists to be 2x12 @12" o.c. or double 2x12 @24" o.c. Please indicate this clearly on the plans.