20081105144735.pdfof EDS City of Edmonds Odd " PLAN REVIEW COMMENTS BUILDING DIVISION �St ggo (425) 771-0220 DATE: October 23, 2008 TO: Amy & Scott Zoloth FROM: Leif Bjorback, Assistant Building Official RE: Plan Check: 2008-0870 Project: Basement Remodel Project Address: 614 Dayton St During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a Permit Coordinator. Redlining of the current set of plans is permitted. 1. What is the size and extent of the Header/Beam at the bedroom? The proposed plan shows it to be unaltered, yet the as -built drawing shows a solid framed wall. Please show on the plans all the framing that is supported by this beam (ie. Floor joists, point loads, etc). Also indicate the size of the footing the new 4x4 post is bearing on. 2. Please show smoke alarms in the bedroom and in the vicinity outside the bedroom. These shall be hard -wired and interconnected. Also, provide smoke alarms in all bedrooms throughout the house, in hallways serving bedrooms, with a minimum of one smoke alarm on each floor level. These also shall be hard -wired and interconnected where feasible. R313.2. 3. Show a handrail at the stairway. R311.5.6. 4. Show a guardrail at the open side of the stairway where the stairs are more than 30 inches above the floor. R312.1. 5. Please label the Family Room on the plans. 6. Show how the Furnace room receives combustion. air. If the construction of the house or space consists of unusually tight construction (sealed so tightly that infiltration air is inadequate for combustion), combustion air shall be obtained from the outdoors per M1702. In this case the furnace room will need to be fully insulated and door weatherstripped. If the space is not of unusually tight construction, please show the size and location of combustion air vents into the furnace room.