Loading...
20081118083654.pdfInc 1,800 GARY HAAKENSON CITY OF EDMONDS MAYOR 121 STH AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 - FAX (425) 771-0221 Website: wwwdedmonds.wa.us DEVELOPMENTS ERVICES DEPARTMENT Planning • Building • Engineering November 18, 2008 Mr. Ron Steinman oshunroamer@aol.com RE: Request for Alternate Design — Air Admittance Valve @ 10506 235" PI SW Dear Mr. Steinman, The City is in receipt of your request for alternate design (reference building permit #2008-0020) for installation of an air admittance valve on the kitchen sink and the island sink. For clarification, the City Building Inspector first performed a rough in plumbing inspection at your house on October 24, 2008 where he noted the lack of foot venting at the kitchen sink as required by the approved plans. In a subsequent phone conversation with our inspector, your plumber was told that in order to be allowed to use an air admittance valve, it would need to be demonstrated through the city's process for "alternate methods and materials" that a foot vent would not be easily achieved, due to structural or other constraints. Based on our field knowledge that conventional venting can be provided, especially in new construction such as in this case, the current request for use of air admittance valves is denied, as it is the City's contention that conventional venting can be provided at minimal disruption to the floor joists and structural members while still maintaining minimum slope for the drain. Sincerely, 9a�L- Ann Bullis, CBO Building Official ' Incorporated August 11, 1890 • Sister City - Hekinan, Japan