2009-0485 Public Storage Fire Repair.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: August 6, 2009 TO: Steve Hopkins Millennium Construction 16625 Redmond Way #207 Redmond, WA 98052-4444 Millennium_con@msn.com FROM: Leif Bjorback, Assistant Building Official RE: Plan Check: 2009-0485 Project: Public Storage Fire Repair th Project Address: 22510 76 Ave W During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a Permit Coordinator. Thank you. 1.Please indicate on the plans the location of Building F on the lot. It is not clear which building this is, as the buildings on the reference drawings are numbered, not lettered. 2.Please indicate on the front of the plans the scope of work, including a clear delineation of the extent of the reconstruction of Building F. Include the extent of roof framing and roof covering alterations. (Previous email correspondence had indicated that the roof deck will be completely replaced over the entire building.) A reduced scale site plan (on the front page) would be helpful. 3.Engineer of Record, please provide a statement of your evaluation of the existing slab and foundation as to its current structural viability. 4.Provide basic building code information on the front of the plans as to which code is used, type of construction, occupancy group, and floor area of the entire building as well as the reconstructed portion. 5.Accessibility for the building is required per IBC Chapter 11. Depending on the number of units in the building, several units shall be accessible, the number dispersed between classes of unit type. Accessible units with man doors shall have accessible doorways as per ANSI A117.1 Section 404 (with 32” clear opening, lever style hardware, maximum ½” high threshold, etc.) Accessible units with overhead doors may have a compliant man door added, or provide an automatic overhead door opener with battery backup and interior and exterior controls. IBC 1103.2.2, 3409.6 and 1108.3 6.Please complete the attached Special Inspection Agreement form attached. 7.Please address the attached structural comments from Eagle Eye Consulting. Page 2 of 2