Loading...
20100512104459583.pdfDATE: 5/6/10 TO: Wayland Constrution 23301 23`d Dr NE Arlington, WA 98223 RE: Plan Check: BLD20100175 Project: Chrastka Addition/Remodel Project Address: Same During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a Permit Coordinator. 1. Provide a foundation plan. Include the existing foundation that is impacted by the second story addition. 2. Show access to crawl space, if applicable. 3. Provide a floor framing plan for new framing. Include the identification and calculations for the beam, located at the jog in the plan offset 12" from the overhead door, which will be carrying the upstairs roof load. 4. Provide a roof framing plan and include overframing members. 5. Provide a cross section from the foundation to the top of the roof framing that includes the proposed GLB at the addition over the garage. 6. Provide a cross section from the foundation to the top of the roof framing that includes the proposed GLB at the living room addition. 7. Identify 5/8" type X gypsum board underneath the living space above the garage. Pat Lawler, CBO patrick.lawler@ci.edmonds.wa.us Plans Examiner 425 7710220 x1703