PLAN REVIEW COMMENTS
BUILDING DIVISION
(425) 771-0220
DATE: August 10, 2011
TO: Jessica Iverson
Email: jiverson@cmarch.com
FROM: Leif Bjorback, Assistant Building Official
rd
RE: Plan Check: 2010-0654 3 review
Project: OReilly Auto Parts
Project Address: 23005 Highway 99
During review of the plans for the above noted project, it was found that the following information,
clarifications or changes are needed. Please provide written responses as to where the changes can
be found on the plans, and submit revised plans/documents to a Permit Coordinator. Text in italics
indicates a previous review comment. Thank you.
1.Required special inspections have been identified for the project. They will include soils
inspections by the geotechnical engineer as well as structural special inspections for
concrete, steel and high (strength) bolting. Please fill out, sign and return the attached
special inspection agreement forms (one for each agency). As your recent email stated, we
are still awaiting the signed special inspection form for soils, as well as the signature on both
forms by the general contractor.
2.Response acceptable.
3.Suspended ceilings with areas exceeding 2500 square feet are required to incorporate a
seismic separation joint or a a full height wall partition that breaks up the area. Please
show on the plans how this will be accomplished. For more information please refer to Field
Technical Document 401 as found at the NW Wall and Ceiling Bureau website.
www.nwcb.org The revised sheet F1 now has additional details for the ceiling system, but
does not include design and detail for a seismic separation joint or a full height wall partition
as requested. Please provide this information on the plans.