Loading...
20100820144405383.pdfTo: Eagle Eye Consulting Engineers, P.S. PO BOX 523 Olalla WA 98359 m hoytjeter@centurytel.net 360 874 0562 Fax 360 874 0591 Emerald Fire Protection 11021 Cramer Road KPN Gig Harbor, WA 98329 Compass Health — Aurora House 20903 70t' Ave W Edmonds, WA 98020 Plan Review Number # 2010-0523 Task Orde 10-08 Thursday, August 5, 2010 EECE E' I" '1 lei -iii„ The above referenced project is in the process of plan review for compliance with Edmonds ordinances and applicable codes (Fi e,: Su :-) ress uo n oifly). The following comments, deficiencies/corrections must be addressed prior to completion of plans review and subsequent issuance of permits. Provide revised plans and calculations along with a written response to each of the items listed below to facilitate a shorter back -check time. SCOPE OF REVIEW The scope of this review is for kire Suppression requirements of this project. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Page 2 of 2 EECE# EDM10-05 Compass Health- Aurora House BLD2010-0523 Task Order 10-08 FIRE SUPPRESSION COMMENTS Sheet 2: Floor Plan View 1. There is no seismic bracing shown or specified on the plans. This review is assuming that the pipe is attached directly to the ceiling trusses. If not, then seismic bracing will be required and plans must be resubmitted showing the bracing. Please clarify this on the drawings. NFPA 13R, 6.13 (2007) 2. In the shower and tub rooms, please relocated the sprinkler heads so that they entirely cover the recessed spaces occupied by the tub and the shower. NFPA 13R, 4.1 (2007) 3. In both the Rec Room and Dining Room, it appears that the there are vaulted ceilings which occupy only a part of the room's ceilings thereby creating ceiling pockets. These pockets are large enough to require sprinkler heads inside the pockets. NFPA 13, 3.3.4 (2010) for definition of pocket & NFPA 13R, 6.8.1.5.4 (2007) Additional corrections may be required following receipt of corrections and additional information as requested. Your plans are being reviewed concurrently with the Building Department, Fire Department, Zoning Department and Public Works Engineering. Changes, clarifications or additional corrections may be required subsequent to the Building Department plan review when comments are received from the other concerned departments. Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (360) 874- 0562 between 8:00 a.m. and 5:00 p.m. By: Hoyt Jeter PE President