Loading...
20105 MAPLEWOOD DR-SITE PLAN 4.pdfNW 114, SEC 19, TWP 27N, RGE 4E, W.M. 2" x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2" 14 GA WIRE FABRIC EQUAL NATIVE BACKFiLL MATERIAL FILTER FABRIC MATERIAL IN CONTINOUS ROLLS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE 2" x 2" WOOD/STEEL POSTS WIRE MESH FENCE o TO SUPPORT FILTER I FABRIC BURY BOTTOM OF FILTER N MATERIAL 8" TO 12' NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT. CITY INSPECTION REQUIRED ON 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ALL EROSION CONTROL METHODS ACTIVITY. BEFORE OTHER WORK CAN BEGIN - REVISION DATE FILTER FABRIC FENCE AUGUST 2017 CITY OF EDMONDS FILTRATION SYSTEMS PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH E R — 9 00 RESIDENCE o �-CLEANOUT a WITH 45• BEND AND CAP CL EANOUT (MAX) TYP NOT TO EXCEED 100' BETWEEN CLEANOUTS CLEANOUT (WYE WITH CAP AND CLEANOUT COVER) AND CONCRETE LEVELING COLLAR 2" f r- FNNISHED GRADE 12" LOCKING COVER SEE NOTE 3 END OF PIPER GRIPPER PLUG (CHERNE 27061 OR APPROVED EQUAL) \- WATER TIGHT CAP 45• RISER SEEELING NOTECOLLAR 45' 12" PVC SLEEVE / 6" RISER 4" OR 6" SIDE SEWER 6" WYE AND r 6" CITY STUB GENERAL CLEANOUT DETAIL 45• BEND rJ 4" OR 6" 12" LOCKING COVER SIDE SEWER CLEANOUT DETAIL 3 z SEE NOTE 3 AT PROPERTY LINE/CITY EASEMENT w LEVELING COLLAR NOTES: z o ?7- (Unj SEE NOTE 4 ASPHALT SURFACE 1. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE GASKETED. 12"f 2. PIPE SLOPE TO BE 2% MIN AND UP TO 50% MAX. 3. SEWER CLEANOUT COVER TO BE EAST JORDAN IRON WORKS 1 FOOT LONG 12" PVC PRODUCT #00366102 STAR PIPE COSP48L OR APPROVED SLEEVE EQUAL. 6" RISER END OF PIPE GRIPPER 4. LEVELING COLLAR SHALL BE CONSTRUCTED AS FOLLOWS: PLUG (CHERNE 270261 OR APPROVED EQUAL) • IN ROADWAYS PER COE STD DWG GU-424 TYPICAL CLEANOUT • IN SIDEWALK/LANDSCAPED AREAS, EITHER 24N24%6" R DEEP CONCRETE COLLAR OR 24" DIAMETER x 6" DEEP UNDER ASPHALT CONCRETE COLLAR `Sf 13'y REVISION DATE CITY OF EDMONDS DECEMBER 2017 SEWER CLEANOUT DETAILS PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH SS-200 _LS a TH IN DE FULL WIDTH DRESS/EGRESS DETAIL NOTES: 1� THE MINIMUM LENGTH SHALL BE EXTENDED AS NECESSARY TO ENSURE MATERIAL IS NOT TRACKED OFF SITE AND/OR INTO THE PUBLIC RIGHT-OF-WAY. O ATB DRIVEWAY RAMP AND/OR SITE ACCESS ROAD 15' WIDE MIN. SEE TABLE BELOW FOR REQUIRED LENGTH. NOTES: 1. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 2. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL QUARRY SPALLS AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. 3. WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO LEAVING THE SITE. WHEN WASHING IS USED, IT SHALL BE DONE ON AN AREA STABILIZED WITH QUARRY SPALLS AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 4. INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN, PROJECT SIZE MIN LENGTH OF (FEET) QUARRY SPALLS* < 1/4 ACRE 30 < 1 ACRE 50 < 3 ACRE 100 > 3 ACRE 100 *PROVIDE ATB OR ASPHALT TRANSITION WHERE FRONTAGE ROAD IS AN ARTERIAL. LENGTH TO BE DETERMINED BY CITY INSPECTOR. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN REVISION DATE `CITY OF EDMONDS STABILIZED CONSTRUCTION AUGUST 2017 ENTRANCE PUBLIC WORKS STANDARD DEPARTMENT ` 1 D ETAI L s I APPROVED BY: R. ENGLISH E R— 9 O x R.O.W. FINISHED GRADE -\ PROPERTY LINE O I rn YCITY METER SUPPLEE BD BALL V�ALVE��, K \ E Li C DIRECTION OF FLOW — —� A D J i MATERIAL LIST: OA ALL 1" SERVICES TO BE TYPE "K" SOFT COPPER TUBING B 1" BALL CORP. STOP WITH CC THREAD INLET AND COPPER (CTS) GRIP OUTLET (FORD OR MUELLER) �C DUAL PURPOSE UNION OD MIPT X CTS GRIP BALL VALVE CURB STOP EQUAL TO FORD B84-444Q FOR 1" OWHEN REPLACING EXISTING SERVICES: 1" METER SETTER WITH ANGLE BALL METER VALVE 15" HIGH WITH DUAL PURPOSE UNIONS ON INLET AND OUTLET, HORIZONTAL IN HORIZONTAL, OUTLET EQUAL TO FORD VB74-15W-11-44 WHEN PLACING NEW SERVICES: USE SAME AS ABOVE AND ADD A SINGLE CHECK, EQUAL TO FORD VBH74-15W-11-44 F 1" CC TAP SERVICE SADDLE EQUAL TO ROMAC 101S �G IN UNPAVED AREAS: CARSON 1324 MSBCF WITH DUCTILE IRON COVER AND CAST IRON READER DOOR; IN PAVED AREAS: ARMOR CAST A6001946PCX12 BOX W/ A600196969 RCI LID O FOR VACANT LOT (FUTURE USE) LOCATION MARKED WITH PAINTED 2" X 4" STAKE WITH "WATER" STENCILED ON IT �I 14 GA. VINYL COATED WIRE TRACER (TAPED TO PLASTIC PIPE EVERY 10') TO BE GROUNDED AT METER AND HOUSE J SCHEDULE 40 3/4" OR 1' PLUG, REMOVE WHEN CONNECTION IS MADE TO CUSTOMER LINE WITH COMPRESSION FITTING K WATER SERVICE TO HOUSE, INSTALLED BY OWNER/CONTRACTOR (PER PLUMBING CODE) OL PROPERTY OWNER RESPONSIBLE FOR PURCHASING 3/4" OR 1" METER THROUGH THE CITY AT DEVELOPMENT SERVICES DEPARTMENT; CITY WILL SUPPLY AND INSTALL METER AFTER PURCHASE; IF USING 3/4" METER, CONTRACTOR WILL PROVIDE REDUCERS OM BACK SIDE OF METER BOX SHALL BE SET AT THE PROPERTY LINE UNLESS APPROVED BY THE CITY ENGINEER. METER BOXES SHALL NOT BE SET IN DRIVEWAY AREAS UNLESS TRAFFIC RATED BOX IS APPROVED BY CITY ENGINEER. REVISION DATE 3/4" -1 APRIL 2017 OF EDMONDS WATER SERVICE PUBLIC WORKS STANDARD INSTALLATION , DEPARTMENT DETAIL APPROVED BY: R. ENGLISH WA— 130 CITY OF EDMONDS PUBLIC WORKS DEPARTMENT SUPPORT POSTS NOTCHED GRADE -� BOARD, 2N2" NOTCHES, 18" O.C. CATCH BASIN FILTER SOCK WITH OVER FLOW HOLES (TYP) :IN NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE-THIRD FULL, 3. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. TEMPORARY SEDIMENT TRAP FOR CATCH BASINS APPROVED BY: R. ENGLISH REVISION DATE AUGUST 2017 STANDARD DETAIL ER-902 END CAP OR PLUG CLEANOUT (TYP) PERFORATED PVC C , UNDERDRAIN PIPE FLOW TO OTHER h DISPERSION TRENCH(ES) IF NECESSARY ' TYPE 1 OR 1-L CATCH TYPE 1 OR BASIN W/SOLID COVER 1-L CATCH -.,. PER STD DETAIL BASIN W/SOLID SD-303 OR SD-304 COVER PER r I . . STD DETAIL SD-30OR ;,: z >`". S SD-304 � � m PIPE FROM ROOF :. DOWNSPOUT 10' (MIN) PLAN NTS --i 2" (TYP) 2" GRADE BOARD 1-18„ oc—i GENERAL NOTES: NOTCHES (TYP) NOTCH DETAIL 1. REFER TO THE 2017 CITY OF EDMONDS STORMWATER ADDENDUM FOR SETBACK AND INFEASIBILITY REQUIREMENTS. 2"02" PRESSURE TREATED GRADE BOARD VEGETATED FLOW SEE NOTEH, *15% MAX FOR FLOW CONTROL/WATER NOTES: QUALITY TREATMENT IN RURAL AREAS. M P 20%, MAX* -do . "" 1. A VEGETATED FLOW PATH MUST BE PROVIDED IN ACCORDANCE THE 2017 CITY OF EDMONDS STORMWATER ADDENDUM REQUIREMENTS. GALVANIZED BOLT (TYP) 2. GEOTEXTILE SHALL CONFORM TO WSDOT SPEC. r. �1 9-33.2(1), GEOTEXTILE FOR SEPARATION, �• z a : ... ' r • NON -WOVEN TYPE. , 3, WASHED DRAIN ROCK SHALL CONFORM TO M I;Ir. WASHED DRAIN WSDOT SPEC. 9-03.12(5), GRAVEL BACKFILL ROCK, SEE NOTE 3 FOR DRYWELLS. O 4" (MIN) PERFORATED 6" (MIN)-� %•",' :PVC UNDERDRAIN PIPE PER WSDOT SPEC. LAID LEVEL GEOTEXTILE, SEE NOTE 2 4N4" PRESSURE UNDISTURBED TREATED SUPPORT POST NATIVE SOIL SECTION _ NTS �- REVISION DATE CITY OF EDMONDS TYPICAL DISPERSION DECEMBER 2017 TRENCH WITH NOTCHED ' PUBLIC WORKS GRADE BOARD STANDARD ` DEPARTMENT DETAIL �S t£ g9� APPROVED BY: R. ENGLISH S D — 6 3 2 R ARoA R01'FO O'OFR�C °N D � c qsA qT£ �► S :1 DRIVEWAY APPROACH (WITHOUT CURB) 01 SAWCUT EDGE o > aw EXISTING ASPHALT ate. a STREET \ V� Rf£S 4" HMA �2 2"-5/8" MINUS CSTC COMPACTED SUBGRADE r SECTION A —A NOTES: 01 SAWCUT AND USE TACK COAT BETWEEN ROAD TO DRIVEWAY APPROACH JOINT, SEAL JOINT WITH AR4000 SEALER. DRIVEWAY APPROACH TO BE 4" HMA CLASS 1/2" PG 64-22. O SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DENSITY, O 10' EDGE RADIUS. Q HMA SHALL BE PLACED FROM EDGE OF EXISTING STREET, A MINIMUM DISTANCE OF 20-FT OR TO PROPERTY LINE, WHICHEVER IS GREATER. i s13 rrrrrrrrrrrrrrrr REVISION DATE DRIVEWAY APPROACH DECEMBER 2017 CITY OF EDMONDS TYPE VI PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH TR — 5 46 6" MIN DEPTH fitter fabric SET DEPTH AS REO'D FOR POST T/ VE FLOW FROM WALL/HOUSE F0077NG DRAIN axnpacted backfill 6' too• pyf • 4" rigid or 6' flexible q 99, 070perforated pipe 24' a q a o a q Qoo , 12' a qo� �p a q washed rock o� O 00apac �1112"-3J4' 4 4 I-�+—•— 24'� SECTION A NTS FOOTING DRAIN DRYWELL TRENCH NOT TO SCALE RES�:. NOV 13 2018 BUILDING nFPART�AFN7 APPROVED FOR CONSTRUCTION CITY OF EDMONDS BY CITY ENGINEERING DIVISION RA ENGINEERING, INC. Civil Engineering / Land Planning 16531 13TH AVE W, SUITE Al08 LYNNWOOD, WA 98037 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM Z O U O Z Z U C� N 41 cr- � of � o � �gT L of wAsz" d O � 38608 9 �� \� �'GISTE�r� IONet . ENGINEER: ROB L. LONG, PE DRAWN BY.• MIKE MORRIS ISSUE DATE. • SCALE: 7110118 AS NOTED JOB NO. 18-Dos SHEET.• DT-01 SH T 4 OF 41