2011-0669 Trieu SFR.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: February 10, 2012 TO: Brian Thaete Email: Brianthaete@hotmail.com FROM: Leif Bjorback, Assistant Building Official RE: Plan Check: 2011-0669 nd Project: Trieu Residence, 2 review Project Address: 7109 Lake Ballinger Way During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a Permit Coordinator. Previous comments that recur on Thank you. this list appear in italics. 1.Engineer of Record: a.Addressed b.Addressed c.Addressed d.Addressed e. There are some omissions from the calculation package to the architectural sheets, e.g. note There are regarding anchor bolt size and placement, and a number of references to details. still significant omissions on sheet 5, including the missing P1-4 label in BR#2, and the 5040 Office window that is shown on the plans, but not in the calcs. Also, The note on calc sheet A1: “Grid C Anchor Bolts @12” oc” does not appear on the foundation plan. Please review the plans to ensure all structural design elements are included on the plan sheets. f. Provide information on the plans as to how Sunroom roof framing ledger connection detail. the ledger is attached to the wall and how the rafters are attached to the ledger. g.Addressed h.Addressed Slab perimeter insulation and thermal break actually is not i.How will a thermal break… needed where the elevation of the slab is more than 2 feet below exterior grade. You may choose to revise the drawings accordingly if you wish. j.Addressed k.Provide lateral load transfer details for the upper floor P1-4 shear walls above the garage Your response says to provide floor framing and deck sheathing to extend to the foundation. to the garage walls, but this is not shown on the plans. l.Addressed m.Addressed 2.Items #2 through #11 have been adequately addressed. New comment: Please add architect’s stamp and signature to all pages in the plan set.