2012-0693 Pinsoneault garage.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: August 29, 2012 TO: Terry Willey awhomes@comcast.net FROM: Chuck Miller, Plans Examiner RE: Plan Check: 2012-0693 Project: Pinsoneault garage th Project Address: 818 9 Avenue S During a review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, cloud all changes on the revised plans, and submit the revised plans/documents to a Permit Coordinator. Thank you. On page 1: 1.Floor Plan - Indicate the required roof ventilation per R806.1. 2.Floor Plan - Indicate the required attic access per R807.1. 3.Floor Plan – Clarify the callout for braced wall type ‘F’ at each side of the one-car garage door opening. The wall width dimensions shown are less than that noted in the ‘Wall Bracing Panel Schedule’ on page 2. The ‘Method PFH – Portal Frame with Hold-downs’ could be used at this location per R602.10.3.3 – see attachment. 4.Cross Section – Indicate the required 18” depth below grade for the bottom of the footing per R403.1.4.1 – see review note #10 below. 5.Cross Section – Indicate the required minimum footing reinforcement placement of one #4 at the top and the bottom of the footing or two #4 in the middle third if cast monolithically per R403.1.3.2 see review note #11 below 6.Cross Section – Indicate the required truss to wall connection per R802.10.5. 7.Cross Section – Indicate the required braced wall connection to roof framing per R602.10.6.2 – see review note #13 below. 8.Cross Section – Indicate the required roof sheathing connection to roof framing/trusses (including boundary nailing) per Table R602.3(1) – see review note #14 below. 9.Provide a reference to the ‘Cross Section’ where applicable to guide proper construction and inspection. On page 2: 10.Mono Garage Footing – Indicate the required 18” depth below grade for the bottom of the footing per R403.1.4.1 – see review note #4 above 11.Mono Garage Footing - Indicate that the required minimum footing reinforcement placement of two #4 in the middle third is if cast monolithically per R403.1.3.2 – see review note #5 above. 12.Provide a reference to the ‘Mono Garage Footing’ where applicable to guide proper construction and inspection. 13.Manuf. Truss @ Flat Ceiling – Indicate the required braced wall connection to roof framing per R602.10.6.2 – see review note #7 above. 14.Manuf. Truss @ Flat Ceiling - Indicate the required roof sheathing connection to roof framing/trusses (including boundary nailing) per Table R602.3(1) – see review note #8 above. 15.Provide a reference to the ‘Manuf. Truss @ Flat Ceiling’ where applicable to guide proper construction and inspection. 16.Braced Wall Panel Detail – Clarify the construction requirements contained with this detail – it seems to be a mix of the ‘Portal Frame with Hold-downs’ and the ‘Alternate Braced Wall’ panel. 17.Braced Wall Panel Detail – Note that the ‘LSTHD8’ holdown will not meet the minimum 1800 pound tension load if installed in an endwall location of foundation stemwall. Page 2 of 2