Loading...
2012-1103 Chang SFR2.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: April 4, 2013 TO: The Leren Co., Inc. Attn: Tom Leren tom@lerendesign.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: 2012-1103 Project: Chang SFR rd Project Address: 17306 73 Avenue W During a review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, cloud all changes on the revised plans, and submit the revised Previous comments that recur on this list appear in plans/documents to a Permit Coordinator. italics Thank you. . On page 3: 1.2009 General & Structural Notes – G. Timber Framing – Note #14 – Clarify the difference in the required minimum header - #2 (2)2x8 DF-L – and that noted on pages 6 & 8 - #2 4x8 DF – to guide proper construction and inspection. 2.2009 Washington State Energy Code – fan sizing and glazing percentage data – Indicate on the plans in the spaces provided the ‘Glazing Square Footage’ and ‘Glazing Percentage’ to support the selection of the Table 6-1 ‘Option II’ prescriptive compliance path of the WSEC. It appears that the updated data (due to the window changes in ‘Bedroom #3’ and the ‘Living Room’) was inadvertently omitted. On pages 6, 8, or 9: 3.Provide on the plans the ‘Post, Cap & Base Schedule’ and the ‘Hanger Schedule’ to guide proper installation and inspection. It appears that those items (previously placed on the same pages of building plans dated 11/27/2012) were inadvertently omitted.