20121212100645485.pdfWASHINGTON STATE AMENDMENTS 304.2.2.1 Laboratories and vocational shops. Laboratories or groups of laboratories under the same management and vocational shops in buildings used for educational purposes, and similar areas containing hazardous materials, shall be separated from each other and other portions of the building by not less than a one - hour fire -resistive occupancy separation. Laboratories or groups of laboratories may include accessory support areas such as offices. When the quantities of hazardous materials in such uses do not exceed those listed in Table 3- D or 3-E, the requirements of Sections 307.5 and 307.8 shall apply. When the quantities of hazardous materials in such uses exceed those allowed by Table 3-D or 3-E, the use shall be classified as the appropriate Group H Occupancy. Laboratories having an occupant load of 10 or more shall have at least two exits or exit -access doors from the room and all portions of the room shall be within 75 feet (22 860 mm) of an exit or exit -access door. 304.5 Light, Ventilation and Sanitation. In Group B Occupancies, light, ventilation and sanitation shall be as specified in Chapters 12 and 29. 304.5.1 is not adopted. 304.5.2 is not adopted. ill / M) cell Section 305 ® Requirements for Group Occupancies 305.1 Group E Occupancies Defined. Group E Occupancies shall be: Division 1. Any building used for educational purposes through the 12th grade by 50 or more persons for more than 12 hours per week or four hours in any one day. Division 2. Any building used for educational purposes through the 12th grade by less than 50 persons for more than 12 hours per week or four hours in any one day. Division 3. Any building or portion thereof used for day care purposes for more than six persons. EXCEPTION: Family child day care homes shall be considered Group R, Division 3 Occupancies. For occupancy separations, see Table 3-13. Effective 7/01/01 D 0 90 NOTICE TO PERMITTEE AND/OR OWNER J,K] CORRECTION REQUIRED El ENFORCEMENT VIOLATION Owner Permit Number Job Address�� ❑Site Contact Type of Inspection 11 WORK DESCRIBED BELOW HAS BEEN INSPECTED AND APPROVED. El APPROVED PLANS AND JOB CARD MUST BE AVAILABLE TO INSPECTOR ON SITE. KI CO RRE CTIONS LISTED BELOW MUST BE MADE BEFORE WORK_ CAN BE APPROVED AND/OR THE NEXT PHASE OF WORK, IS STARTED. ❑ RECALL FOR INSPECTION ❑ REINSPECTION FEE MUST BE PAID PRIOR TO NEXT INSPECTION REQUEST. El STOP WORK -UNTIL AUTHORIZED TO CONTINUE BY CITY INSPECTOR. (j "A 1­1 L r J a"" e; THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED TO BE CORRECTED BY (DATE) OR PENALTIES MAY BE APPLIED. FOR INSPECTION CALL 425-771-0220 00,' Building El Planning D Engineering E] Fire E Public Works Inspector Date White: Permit File Puff: Applicant