2013-0033 Kennebrew deck.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: January 18, 2013 TO: Denise Kennebrew deniseken2@hotmail.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2013-0033 Project: Kennebrew deck st Project Address: 7823 191 Street SW During a review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, cloud all changes on the revised plans, and submit the revised plans/documents to a Permit Coordinator. Thank you. On page 1: 1.Indicate the required attachment of the deck ledger to the primary structure per R502.2.2. Table 502.2.2.1 – found on page 5 of the attached MyBuildingPermit handout – provides fastener spacing for a variety of deck configurations and connection criteria. 2.Indicate the required attachment of the deck ledger for lateral loads per R502.2.2.3. Detail #1/Option #2 – found on page 4 of the attached MyBuildingPermit handout – provides a possible means to meet this requirement. 3.Indicate the required bracing at the north beam line to laterally support the deck structure per R502.2.2. Knee bracing – represented in the ‘Post to Beam Connection w/ Knee Brace’ detail on page 3 of the attached MyBuildingPermit handout – provides a possible means to meet this requirement. ‘Sway -’ or ‘diagonal bracing’, boards attached with 2-16d nails to the underside of each deck joist in a diagonal ‘V’ or ‘W’ pattern, may also be used to meet the requirement. 4.Clarify the method to be used to support the north end of the 7-foot long deck joists at the west end of the deck and the angled, cantilevered joists adjacent the triple-joist. 5.Indicate the framing members and method to be used to construct the mid-level stair landing. 6.Provide a stair section indicating the proposed construction to meet the requirements of R311.7. The ‘Sample Stair Section’, found in ‘Attachment B’of the attached City of Edmonds handout, illustrates the code requirements.