2013-0034 Thorsen garage.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: January 24, 2013 TO: Gerald Thorsen jthorthor@comcast.net FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2013-0034 Project: Thorsen garage Project Address: 7205 Lake Ballinger Way During a review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, cloud all changes on the revised plans, and submit the revised plans/documents to a Permit Coordinator. Thank you. On page 3: 1.Provide the required braced wall panel at the south end of the west braced wall line of the ‘New Garage’ per R602.10.1.4.1. Another braced wall panel must begin within 8’ of the 24” wall at the corner, or another wall bracing method could be used. 2.Provide the required minimum 2’ – 10” braced wall panel length for each of the ‘Alternate Braced Wall Panels – ABWP’ per Table R602.10.3.2. Other wall bracing methods, such as ‘Method PFH – Portal Frame with Hold-downs’, could be used along this braced wall line to maintain the desired 9’ wide garage door opening. Provide the required holdowns at each end of the ‘ABWPs’ per Figure R602.10.3.2. 3.Provide the required anchorage to be used for the ‘HD5B’ – the HD5A is no longer available per the manufacturer. 4.Indicate the required headers to be used over the 5.0x1.0 windows and the 3.0 door along the west wall of the ‘New Garage’. On page 4: 5.Indicate the required roof slope of ¼-inch-per-foot to meet the roof covering installation requirements of R905. 6.Clarify the method to be used to support the east end of the 11-7/8” - ‘TJI 110’ i-joist rafters. 7.Clarify the ‘rafter clips’ to be used to resist wind uplift. Most of the i-joist manufacturers prohibit or limit the placement of fasteners into the sides of the i-joist chords. 8.Clarify the callout for 10” long anchor bolts to be used with 3x6 pressure-treated bottom plate. With the required 7” of embedment into the concrete, ¼” thick plate washers, and at least ½” for the nut (7-3/4”), it appears that the 10” anchor bolts will not allow proper attachment – (10 inches – 7-3/4 inches = 2-1/4 inches). There is no requirement for the bottom plate to be any thicker than 1-1/2 inches, or 2x lumber. 9.Provide the required minimum 12” wide footing supporting the foundation stem wall along the north-south, or west side exterior wall, per Table R403.1. 10.Provide the required frost protection for the footings per R403.1.4.1. The bottom of all exterior footings must be at least 18” below grade to meet this requirement. Page 2 of 2