Loading...
2013-0240 Waite carport conversion-garage addition2.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: April 5, 2013 TO: J. K. Yamane jkyamane@comcast.net FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2013-0240 Project: Waite carport conversion-garage addition nd Project Address: 1154 2 Avenue S During a review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, cloud all changes on the revised plans, and submit the revised plans/documents to a Permit Coordinator. Thank you. On page A-1: 1.Wall Section AA/A-1 – Clarify the callout for the (2) 2x8 HF #1/btr rafters at 16” on-center. The deflection of the overhang is beyond the L/240 allowed per Table R301.7. 2.Existing and Proposed Roof Plan – Verify that the callout for the new rafters over the 6-foot and 10-foot additions to the existing carport is the same as indicated elsewhere on the building plans – see ‘Wall Section AA/A1’ and the response to above review comment.