Loading...
2013-0268 Horn remodel.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: April 4, 2013 TO: Doug Hannam Port Gardner Architects Email: dnhannam@frontier.com FROM: Leif Bjorback, Building Official RE: Plan Check: 2013-0268 Project: Horn Residence Remodel th Project Address: 18224 84 Pl W During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a permit coordinator in the Development Services Department. Thank you. 1.Detail 6/S2 has a note to excavate existing footing in max. 4 foot sections; however page 2 of the March 1, 2013 soils addendum, item 5B, states the sections should be 3 feet or less, unless temporary shoring is provided. Please address this on the plans. 2.Please provide gravity calculations for all glulams, parallams, beams with point loads or in excess of 8 feet in length. 3.The structural calculation packet does not contain a shearwall schedule as referenced. Please provide. 4.EOR, please review all structural pages in the plan set for accuracy and completeness in accordance with the lateral design, and either stamp and sign each of these pages or provide a letter indicating your approval of the same. 5.The following discrepancies were noticed upon comparison of the engineering calculations for the lateral design and the working plans. a.Verify the accuracy of the contents of the shearwall schedule on S1. b.In the shearwall schedule include elements required for P1-3 since there is at least one P1-3 wall indicated in the calculations. c.On sheet S2, the walls are noted as P1-4 walls at the middle level of the north elevation, but are noted in the calcs as P1-3. Please address. d.On sheet S3, the north elevation shows P1-4 panel lengths of 3’-9 ½” and 4’. The calcs indicate panel lengths of 5’ and 4’ at all 3 levels. Please justify the narrower panels or revise the plans to reflect the calcs. e.The calcs for the Middle Level-South Wall-Back side of Lower level indicate one 36 foot long P1-6 panel; however, the South Elevation-Grid D/S4 shows 2 panels with considerably less length. Please clarify the application. f.On sheet S5, clarify whether the rear garage wall at gridline D should be shown as a P1-6 on the Upper Level Plan. It appears the calcs include this wall (Upper Level, South Wall between house and garage) in the lateral design. g.On sheet S5, it appears the shearwall layout on gridline 2 at Upper Level-East Wall does not match the design in the calcs. See also the East Elevation on sheet S3. Please revise the calcs or the plans as needed. h.On sheet S5, on the Mid Level and Lower Level Plan please show the holddowns on the shearwalls that are indicated in the calcs for the Lower Level- Middle Wall. i.Clarify on the plans the type of shearwalls at the elevator at all floor levels. Also, clarify the note on sheet A4 “New SW at each side of elev.” This does not seem consistent with the structural design. Page 2 of 2