2013-0323 Echelbarger SFR.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: May 3, 2013 TO: Todd Echelbarger todd@echelbarger.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2013-0323 th Project: Echelbarger SFR – 86 Place th Project Address: 18129 86 Place W During a review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, cloud all changes on the revised plans, and submit the revised plans/documents to a Permit Coordinator. Thank you. On page A-6: 1.Clarify the callout for the size of the isolated footings below the following point loads: The column supporting the ends of both ‘Beam 10’ over the garage. · The column supporting the ends of both ‘Beam 2’ over the garage. · The column supporting the north end of ‘Beam 12’ over the Dining Room entrance · to the Hall – see also plan review note #2. The footings appear to be undersized for the loads noted in the provided beam calculations at those locations. On page A-7: 2.Clarify the callout for ‘Beam 12’ – 5-1/2x9-1/2 2.0E PSL – per product manufacturer there are no PSLs 5-1/2 inches wide. Also, the span noted in the provided calculations appears to be less than that shown on the building plans, resulting in a different distribution of loads at each end – see plan review note #1. 3.Clarify the callout for ‘Beam 11’ – 5-1/4x9-1/2 2.0E PSL. It appears to be over spanned – the provided structural calculations note a 5-1/4x11-7/8 2.0E PSL at that location. 4.Clarify the callout for ‘Beam 1’ – 5-1/4x9-1/2 2.0E PSL. It appears to be over spanned – the provided structural calculations note a 5-1/4x11-7/8 2.0E PSL at that location. 5.Indicate on the plans the required hanger for the connection of the north end of ‘Beam 8’ – 1-3/4x11-7/8 1.9E LVL – to ‘Beam 13’ – 5-1/4x14 2.0E PSL – to guide proper construction and inspection. On page A-8: 6.Clarify the length of wall bracing shown along the west wall of ‘Bedroom 4’ – braced wall line ‘2’ on level ‘2’. The provided structural calculations note a longer braced wall at that location – page 4.1 and schematic. On page A-12: 7.Indicate on the plans the option(s) to be used to develop the one credit from Table 9-1 required per WSEC section 901. Page 2 of 2