2013-0593 Barnsdale remodel-addition2.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: July 29, 2013 TO: Bill & Joy Barnsdale barnsdale.bill@gmail.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2013-0593 Project: Barnsdale remodel-addition Project Address: 18133 86th Place W During a review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, cloud all changes on the revised plans, and submit the revised plans/documents to a Permit Coordinator. Items that recur on this list appear in italics. Thank you. General note: 1.Indicate on the plans the method to be used to provide the required whole house ventilation per M1508. Per R102.7.1, additions, alterations or repairs to any structure shall conform to the requirements for a new structure without requiring the existing structure to comply with all of the requirements of this code, unless otherwise stated. Additions, alterations or repairs shall not cause an existing structure to become unsafe or adversely affect the performance of the building. Only additions with less than 500 square feet of conditioned floor area are exempt from the requirements for Whole House Ventilation System, Section M1508. On page A7: 2.Indicate on the plans the proposed construction (deck surface, joist species and grade, joist size, joist spacing, joist cantilever, ledger species and grade, ledger attachment, beam species and grade, beam size, beam cantilever, post species, post spacing, footing size and depth, post/base and post/beam connections) of the ‘wood frame patio/landing’ at the east end of the Master Bedroom.