Loading...
2013-0698 Reis Garage.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: August 13, 2012 TO: Belton Homes, LLC terri@sundquisthomes.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: 2012-0578 Project: Stonebridge Court, Lot 8 th Project Address: 21913 78 Place W During a review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, cloud all changes on the revised plans, and submit the revised plans/documents to a Permit Coordinator. Due to the relatively minor nature of the following comments, the changes may also be made by ‘red-lining’ the existing plans in-person. Thank you. On page A3: 1.Provide a callout for ‘Detail 2’ on page G1 for the continuous footings/foundations to guide proper construction and inspection. On page A5: 2.Change the code reference for the required dwelling/garage fire separation from ‘R309.2’ to ‘R302.6’. 3.Change the code reference limiting the stair riser height from ‘R311.5.3.1’ to ‘R311.7.4.1’. On page A6: 4.Provide a callout for ‘Detail 1’ and ‘Detail 2’ on page A6, where applicable, for the shear wall/ floor diaphragm configuration to guide proper construction and inspection. On page A7: 5.The 150 cfm ‘Whole House Fan’ in the laundry room meets the requirements of a continuously operating fan per M1508.2 (75 cfm for the optional maximum of 4 bedrooms / 1501- 3000 sq. ft.). Operated intermittently (for 1 hour every 4 hours), a 300 cfm fan would be required. On page A8: 6.Clarify the callout for the header over the window in the west wall of the ‘Bonus Room’ – the typical #2 DF 4x8 is over-spanned.