2013-0922 Winterer patio cover.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: September 10, 2013 TO: Jeff Raemer jeffraemer@gmail.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2013-0922 Project: Winterer patio cover th Project Address: 9230 215 Street SW During a review of the plans for the above noted project, it was found that the following information, clarifications, or changes are needed. Please provide written responses as to where the changes can be found on the plans, cloud all changes on the revised plans, and submit the revised plans/documents to a Permit Coordinator. Thank you. 1.Indicate on the plans the required fasteners (diameter and length, screw or bolt) and on- center spacing used to attach the ledger to the structure. 2.Indicate on the plans the building element that the patio cover ledger is being attached to. It must be capable of supporting the additional load of the patio cover (not fascia or the ends of roof rafters). 3.Provide specifications on the ‘corrugated roof’ material to be used as a roof covering and the means of attachment required to resist the component and cladding loads (wind/uplift) specified in Table R301.2(2). 4.Clarify the callout for 1x6 cedar to be used as roof rafters. The 1x material does not meet the structural requirements of R802.5 or the American Forest & Plywood Association (AF&PA) for use as rafters. 5.Clearly indicate on the plans the locations of the 4x8 cedar beams, their bearing points, and required footings to support the loads. One of the beams is identified, and a few others appear to be represented, but all appear to be over spanned. 6.Indicate on the plans the portion of the existing patio cover that is to be repaired and/or retained for use.