2013-0940 Zettler remodel.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: September 9, 2013 TO: Jun Fernando junfernando57@yahoo.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2013-0940 Project: Zettler remodel th Project Address: 434 12 Place N During a review of the plans for the above noted project, it was found that the following information, clarifications, or changes are needed. Please provide written responses as to where the changes can be found on the plans, cloud all changes on the revised plans, and submit the revised plans/documents to a Permit Coordinator. Thank you. On page 2: 1.Indicate on the plans the required beam to support the load over the window added in the master bathroom. Provide roof framing details (‘stick-framed’ rafters or manufactured full- span trusses, ceiling joists, etc.) and the span of the structure used in determining the beam size. 2.Indicate on the plans the required beam to support the load over the window enlarged in the master bedroom. Provide roof framing details (‘stick-framed’ rafters or manufactured full- span trusses, ceiling joists, etc.) and the span of the structure used in determining the beam size. 3.Provide a detail for the construction of the replacement deck guards. The design shall meet the requirements of R312 (minimum 36 inches above the walking surface, restrict the passage of a 4 inch sphere, etc.).