2013-0940 Zettler remodel2.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: September 23, 2013 TO: Jun Fernando junfernando57@yahoo.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2013-0940 Project: Zettler remodel th Project Address: 434 12 Place N During a review of the plans for the above noted project, it was found that the following information, clarifications, or changes are needed. Please provide written responses as to where the changes can be found on the plans, cloud all changes on the revised plans, and submit the revised plans/documents to a Permit Coordinator. Items that recur on this list appear in italics. Thank you. On page 5: 1.Indicate on the plans the required beam to support the load over the window enlarged in the master bedroom. Provide roof framing details (‘stick-framed’ rafters or manufactured full- span trusses, ceiling joists, etc.) and the span of the structure used in determining the beam size. The orientation of the roof framing shown appears to be inconsistent with the site conditions represented in aerial views of the structure that suggest a gable-type roof structure with one side bearing on the west exterior wall. The width of the structure in the same direction as the roof framing, along with the length of the roof overhang, is necessary to determine the load to be supported by the beam over the master bedroom window.